Wireless Controller
User Manual
Rogue Detected Trap Interval: Specify the interval, in seconds, between
transmissions of the SNMP trap telling the administrator that rogue APs are present
in the RF Scan database. If you set the value to 0, the trap is never sent.
De-Authentication Requests Threshold Interval : Specify the number of seconds
an AP should spend counting the DE authentication messages sent by wireless
clients.
De-Authentication Requests Threshold Value: If controller receives more than
specified messages during the threshold interval the test triggers.
Authentication Requests Threshold Interval : Specify the number of seconds an
AP should spend counting the authentication messages sent by wireless clients.
Authentication Requests Threshold Value : If controller receives more than
specified messages during the threshold interval the test triggers. Probe Requests
Threshold Interval Specify the number of seconds an AP shoul d spend counting the
probe messages sent by wireless clients.
Probe Requests Threshold Value: Specify the number of probe requests a wireless
client is allowed to send during the threshold interval before the event is reported
as a threat.
Authentication Failure Threshold Value: Specify the number of 802.1X
authentication failures a client is allowed to have before the event is reported as a
threat...