Rlx2-Ihnf-W; Rlx2-Ihnf-Wc - ProSoft Technology RLX2-IHW User Manual

Hide thumbs Also See for RLX2-IHW:
Table of Contents

Advertisement

RLX2-IHNF-W

1. The equipment shall be properly grounded with the external ground screw provided connected to building ground
as well as the antenna coaxial screen of the connector shall be grounded.
2. The common or earth side of the circuit is connected to the screen of the coaxial cable and to all accessible parts
and circuits.
3. Shall be installed in Restricted Access Location Only.
4. SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR NONHAZARDOUS
LOCATIONS ONLY.
5. WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE
AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS.
6. WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION
2.
7.
WARNING – DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED.
8. Antennas are to be installed in accordance with Control Drawing 06/2514
9. Unit does not comply to the cable assy requirements of ISA 12.12.01 but does comply with the ATEX standards
IEC60079-0 & IEC60079-15. In ATEX environments, do not connect/disconnect unless area is known to be non-
hazardous.
10. Unit must be wired with Phoenix Contact M12 Cable Assemblies, Model Series SAC-HZ-XX-XX-XX/XX-
XXX/XXXXXXXXX, that are suitable for use in Class 1, Division 2, Groups A, B, C, and D Hazardous Locations.

RLX2-IHNF-WC

1. The equipment shall be properly grounded with the external ground screw provided connected to building ground
as well as the antenna coaxial screen of the connector shall be grounded.
2. The common or earth side of the circuit is connected to the screen of the coaxial cable and to all accessible parts
and circuits.
3. Shall be installed in Restricted Access Location Only.
4. SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR NONHAZARDOUS
LOCATIONS ONLY.
5. WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE
AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS.
6. WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION
2.
7. WARNING – DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED
8. Antennas are to be installed in accordance with Control Drawing 06/2514