Be certain the arrow on the magnet and the guide line on the transmitter are
aligned and within ¼ inch of each other.
The sensor tamper switch may be open (cover off).
If a motion sensor goes off continuously, be sure the sensor is mounted on a
solid surface and the viewing field is free from sources of changing temperature.
If a motion sensor does not respond to motion:
Make sure the sensor battery is good and installed correctly. Wait 2 minutes
after installing a new battery to test the sensor.
Adjust the sensor mounting.
Leave the area for 3 minutes, then retest.
The environment may be too hot or too cold. Outdoor sensors operate
between 32 and 120ºF (0 and 49ºC).
Dirt or dust may be causing the problem. Wipe the sensor with a clean, damp
cloth.

Specifications

Power
Radio frequency
Storage temperature
Operating temperature
Maximum humidity
Auxiliary power
Contents
Simon XTi-5 Installation Manual
9 VAC, 60 Hz, 25 VA transformer minimum
Rechargeable battery: 6.0 VDC, 2.1 Ah NIMH. Maximum battery
charging current is 120 mA.
Once the battery reaches a low battery condition, a trouble signal will be
annunciated, indicating that the battery may no longer support a full
alarm load.
When fully charged, the battery will operate the panel without AC power
for 24 hours with the panel in a normal, standby condition, followed by 5
minutes in full alarm condition (including the maximum specified
auxiliary load of 250 mA).
319.5 MHz
-29 to 140ºF (-34 to 60ºC) without battery
14 to 86ºF (-10 to 30ºC) with battery one year shelf life
32 to 120ºF (0 to 49ºC)
85% relative humidity, noncondensing
Unregulated 4.0 to 12.3 VDC, with a maximum of 250 mA
67