Be certain the arrow on the magnet and the guide line on the transmitter are
aligned and within ¼ inch of each other.
•
The sensor tamper switch may be open (cover off).
If a motion sensor goes off continuously, be sure the sensor is mounted on a
solid surface and the viewing field is free from sources of changing temperature.
If a motion sensor does not respond to motion:
•
Make sure the sensor battery is good and installed correctly. Wait 2 minutes
after installing a new battery to test the sensor.
•
Adjust the sensor mounting.
•
Leave the area for 3 minutes, then retest.
•
The environment may be too hot or too cold. Outdoor sensors operate
between 32 and 120ºF (0 and 49ºC).
•
Dirt or dust may be causing the problem. Wipe the sensor with a clean, damp
cloth.
Specifications
Power
Radio frequency
Storage temperature
Operating temperature
Maximum humidity
Auxiliary power
Contents
Simon XTi-5 Installation Manual
9 VAC, 60 Hz, 25 VA transformer minimum
Rechargeable battery: 6.0 VDC, 2.1 Ah NIMH. Maximum battery
charging current is 120 mA.
Once the battery reaches a low battery condition, a trouble signal will be
annunciated, indicating that the battery may no longer support a full
alarm load.
When fully charged, the battery will operate the panel without AC power
for 24 hours with the panel in a normal, standby condition, followed by 5
minutes in full alarm condition (including the maximum specified
auxiliary load of 250 mA).
319.5 MHz
-29 to 140ºF (-34 to 60ºC) without battery
14 to 86ºF (-10 to 30ºC) with battery one year shelf life
32 to 120ºF (0 to 49ºC)
85% relative humidity, noncondensing
Unregulated 4.0 to 12.3 VDC, with a maximum of 250 mA
67