Interlogix XTI-5 Installation Manual page 55

Hide thumbs Also See for XTI-5:
Table of Contents

Advertisement

2. From the Timers screen, press the white field next to the Timer option to edit.
3. Enter the value on the numbered keypad.
OR
To turn an option on, press
Note:
indicates the option is turned on.
4. Press SAVE to save the changes.
5. Press CLOSE to return to the Programming screen.
Table 18: Timers menu
Function
Default
Entry delay
030 seconds
Exit delay
060 seconds
No activity tm
Off
Contents
Simon XTi-5 Installation Manual
. To turn an option off, press
Description
Determines how much time you have to disarm the system
after entering the armed premises through a designated
delay door, before an alarm occurs. Beeps sound during the
entire delay time to remind you to disarm the system. When
turned on, the entry delay can be set from 030 to 240
seconds.
Determines how much time you have to leave the premises
through a designated delay door after arming the system.
Beeps sound after arming the system to remind you to
leave the armed premises. If a delay door is opened after
the exit delay expires, the entry delay begins. If you arm the
system with no delay and open a delay door after the exit
delay expires, an alarm occurs.
Determines whether the panel sends a no activity report to
a central station when the programmed time elapses (on),
or if the feature is disabled (off). No activity means the
control panel, remote handheld, and key-chain touchpad
buttons have not been pressed and sensors have not been
tripped within a specified time (except sensors in group 25
and 43). The timeout can be set from 02 to 24 hours.
.
49