Function
Default
Smoke supervision Off

Touchpad options

To edit touchpad options:
1. From the Programming screen, press TOUCHPAD OPTIONS.
2. To turn an option on, press
Note:
indicates the option is turned on.
3. Press CLOSE to return to the Programming screen.
Table 19: Touchpad Options menu
Function
Default
Keyfob no delay
Off
Panic alarms
On
Remote TP arm
Off
Contents
Simon XTi-5 Installation Manual
Description
Determines how often the panel must receive supervisory
signals from the smoke sensors. If this option is on, the
panel must receive at least one supervisory signal from
smoke sensors every four hours or it will identify a sensor
failure and sound trouble beeps. If this option is off, the time
for receiving supervisory signals is determined by RF
timeout.
. To turn an option off, press
Description
Determines whether a key fob arms the system with no delay (on),
or not (off). When this feature is on, you must disarm the system
before entering the premises, since it is disabling the entry delay.
If the remote touchpad arming option is on, key fobs cannot
disarm the system and will cause an alarm upon entering.
Determines whether the panel panic icons (police, panic, and fire)
activate alarms when pressed (on), or not (off).
Determines whether key fobs and remote touchpads can disarm
the system only during exit and entry delays (on), or arm and
disarm the system anytime (off). If this option and the key fob no
delay option are on, you cannot enter and/or disarm using remote
touchpads without causing an alarm.
.