Interlogix XTI-5 Installation Manual page 43

Hide thumbs Also See for XTI-5:
Table of Contents

Advertisement

Function
Default
Downloader
12345
code
Phone lock
Off
Auto arm
On
Exit extend
On
Secure
Off
arming
No arm on
Off
low battery
Contents
Simon XTi-5 Installation Manual
Description
Lets you set a unique five-digit code that is required for initiating
Enterprise Downloader sessions. The code must be five digits long and
can range from 00000 to 99999. The downloader code must match the
downloader access code in the Enterprise account to perform Enterprise
sessions.
Prevents resetting of phone/reporting related options when a memory
clear is preformed (on) or resets these options to their default values
when a memory clear is performed (off). The following are not reset
when on: account number, dealer code, code length, call wait cancel,
phone numbers 1 to 4, phone report modes 1 to 4, phone lock,
downloader phone number and downloader code.
Determines how long the system protests (announces open/failed
sensors) when attempting to arm with open/failed sensors, before
bypassing these sensors and automatically arming the rest of the
system. The panel protests an arming attempt when it has not received
a restore (close) signal from sensors learned into restore-specific sensor
groups. Sensors learned into group 26 (fire) cannot be bypassed.
When this option is on, the panel announces all open/failed sensors
repeatedly for four minutes, then automatically bypasses the open
sensors and arms the rest of the system. If a sensor is opened during
the exit delay and then left open, the panel will go into alarm after the
exit delay has expired. This option must be on for unvacated premises
and exit extension to work correctly.
When the option is off, the panel displays all open/failed sensors once,
then automatically bypasses the open sensors and arms the rest of the
system after the exit delay has expired. If other sensors are opened
during the exit delay, they will also be bypassed if left open.
If group 13 (instant perimeter) sensors are opened during the exit delay,
the panel goes into immediate alarm.
Determines whether the panel restarts the exit delay time if you enter
the armed premises during the initial exit delay period (on), or not (off).
Turning on this feature allows you to reenter during the exit delay period,
without disarming and then rearming the system. Turning off this feature
requires you to disarm and rearm the system.
Note: Auto arm must be on for this option to work.
Determines whether an access code is required when arming the
system (on), or not (off). This option does not affect key fob arm/disarm
operation.
Determines whether the system protests arming if a low CPU battery
condition exists (on), or not (off).
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents