System function
All lights on
All lights off
System status
Audio verification
Terminate session

Two-way voice operation

For the central station operator to initiate an audio session:
1. After the panel has completed reporting the alarm, pick up the CS phone and
press the * button to start the audio session.
2. Press 1 or 0 to speak, 2 for VOX operation, and 3 or 6 to listen.
3. Press 99 to terminate the session.
Note:
Panel voice announcements are silenced during AVM sessions. If the
operator does not terminate the session correctly, panel announcements may not
occur for up to 90 seconds after the operator hangs up.
Table 28: Audio verification set
Phone button
Function
0 or 1
Speak
2
VOX operation
3 or 6
Listen
7
Extend session for 90 more seconds
88
Terminates session with call back (the panel answers on the first ring if called
within 5 minutes)
99
Terminates session with no call back
Voice event notification
Testing this feature requires two people; one at the alarm site and the other at
the location the panel is programmed to call.
To test voice event notification:
1. Contact the central monitoring station (if the system is monitored) to inform
them you are testing the system and not to dispatch authorities.
2. At the system site, put the system into an alarm condition.
64
Phone command
* *
# #
0
5 plus X (X= a command from Audio Verification Set)
9