Test your sensors by tripping them one at a time. The panel will display the
number of transmissions received from sensors you trip. See Table 23 on
page 57 for specific instructions on how to trip each sensor type.
The panel sounds beeps, and the display identifies the tripped sensor and the
number of RF packets received. Each beep represents one RF packet. Count
the number of beeps and refer to Table 26 below for minimum requirements.
The panel displays Sn (sensor number) Name, and Rounds Detected (#
Packets). Scroll through to make sure all sensors have been tested.
Table 26: Sensor tripping instructions
Sensor
Instructions
Hardwire contact Open the hardwire contact.
Door/window
Open the secured door or window.
Freeze
Remove the sensor cover. Apply ice in a plastic bag to the
sensor (for 10 to 15 minutes). Do not allow the sensor to
get wet.
Water
Press a wet rag or wet finger over both of the round, gold-
plated terminals on the underside of the sensor.
Carbon
Press and hold the Test/Hush button (approximately 5
monoxide alarm
seconds) until the unit beeps two times, and then release
the button.
Glassbreak
Test with an appropriate glass break sensor tester.
Motion sensor
Avoid the motion sensor field of view for 5 minutes, and
then enter its view.
Rate-of-rise heat
Rub your hands together until warm, and then place one
detector
hand on the detector for 30 seconds.
Shock
Tap the glass twice, away from the sensor. Wait at least 10
seconds before testing again.
Smoke
Press and hold the test button until the system sounds
transmission beeps.
Personal help
Press and hold the appropriate help button until the light
button
blinks and the panel sounds for at least seven beeps.
60
Minimum
packets
required
1
6 of 8
6 of 8
6 of 8
6 of 8
6 of 8
6 of 8
6 of 8
6 of 8
6 of 8
6 of 8
Simon XTi-5 Installation Manual