Full line seizure wiring with one premises phone

If a single phone is all that exists on the premises, full line seizure can be
accomplished without an RJ31X.
1. Disconnect the phone from the premises phone jack and plug it into the panel
PHONE jack. This jack is disconnected automatically whenever the panel
reports.
2. Connect the included phone cord to the panel LINE jack and the premises
phone jack.
Note:
If customers add phones or other phone devices to another phone jack, full
line seizure no longer exists. Inform them to contact you if they want to add a
phone or other device so that you can rewire for full line seizure by adding an
RJ31X.
Wiring the power transformer
Connect the power transformer to the two 9 VAC in terminals on the panel.
Note: System can only be powered up using AC power, not battery power. The
red battery icon may appear when system first powers up and will disappear after
some time.
Figure 10: Transformer connections
Do not plug in the transformer at this time. When applying power to the panel
connect the battery first, and then plug in the AC power transformer. This
sequence prevents a battery fault condition.
Note:
Maximum battery charge current is 120 mA. It may take up to 36 hours for
a new battery to fully change.