Interlogix XTI-5 Installation Manual page 46

Hide thumbs Also See for XTI-5:
Table of Contents

Advertisement

Table 13: Phone Options menu
Function
Default
Man phone
On
test
FTC
On
DTMF dial
On
300 bps
On
enabled
Ring hang ring
RHR or
10
Rings
Dial delay
30
seconds
40
Description
Determines whether you can perform a manual communication test to
verify communication to a central station/voice dial (on), or not (off). If
you have all four phone numbers programmed, it should send a test
report to all four before showing that the test is okay.
Determines whether the panel and interior sirens sound trouble beeps
if it is unable to successfully send a report to a central station (on), or
not (off).
Determines whether the panel uses DTMF (on) or pulse (off) for
dialing programmed phone numbers.
Determines whether the baud rate used by the panel for central
station communication is 300 bps (on), or 110 bps (off).
Determines when the panel answers a remote phone access or
Enterprise call. Depending on whether an answering machine exists
at the panel location, offsite access to the panel can be done with a
series of phone calls or just one. For offsite access where an
answering machine does not exist, the user or Enterprise operator
simply calls the panel location once and listens for 10 rings. The panel
should answer after the tenth ring.
For offsite access where an answering machine exists, the user or
Enterprise operator must call the panel location, and then let the
phone ring once and hang up. Wait at least 10 seconds but not more
than 40, and then call the panel location again. The panel should
answer on the first ring.
Ring/hang/ring setting number and sequence of rings after which the
panel answers:
RHR or 10 Rings = Ring/hang/ring or ten rings
RHR(2) or 10 Rings = Ring/hang/ring/hang/ring or ten rings
RHR(3) or 10 Rings = Ring/hang/ring/hang/ring/hang/ring or ten
rings
10 Rings = Ten rings
RHR = Ring/hang/ring
RHR(2) = Ring/hang/ring/hang/ring
RHR(3) = Ring/hang/ring/hang/ring/hang/ring
Off = Disabled, no remote (offsite) access
Determines whether the panel delays dialing programmed phone
numbers before sending report (on).
If opening (disarming) reports is on, the panel does not delay dialing if
the system is disarmed before the delay time expires. The panel dials
immediately for both the alarm and opening report.
Regardless of this option setting, the panel always dials immediately
for fire alarms, AC power failure, and low battery reports.
Simon XTi-5 Installation Manual
Contents

Hide quick links:

Advertisement

Table of Contents
loading