Output Conditioning Parameters; Output Parameters - PR 5350 Configuration Manual

Foundation fieldbus
Table of Contents

Advertisement

2.8.4 Output conditioning parameters

Rel.
Parameter
Index
SENSOR_MEAS_TYPE
BIAS_1
BIAS_2
MAX_SENSOR_VALUE_1
MIN_SENSOR_VALUE_1
MAX_SENSOR_VALUE_2
MIN_SENSOR_VALUE_2

2.8.5 Output parameters

Rel.
Parameter
Index
PRIMARY_VALUE
SECONDARY_VALUE_1
SECONDARY_VALUE_2
INTERN_TEMP
AI_TRANSDUCER Block Parameter List
Description
FF
Mathematical function to calculate PRIMARY_VALUE (PV).
Defined codes:
0: PV = SV_1
1: PV = SV_2
128: PV = SV_1 - SV_2 Difference
129: PV = SV_2 - SV_1 Difference
192: PV = ½ * (SV_1 + SV_2) Average
193: PV = ½ * (SV_1 + SV_2) Average, but SV_1 or
SV_2 if the other is wrong (input_fault_x ≠0)
17
220: PV = SV_1, SV_2 not available. Used for single
sensor applications. If selected, Sensor 2 will
not be measured. All parameters exclusively
related to Sensor 2 are not available, and no
alarms will be generated for Sensor 2.
221: PV = SV_1, but SV_2 if SV_1 is wrong
(INPUT_FAULT_1 ≠0)
222: PV = SV_2, but SV_1 if SV_2 is wrong
(INPUT_FAULT_2 ≠0)
Bias that can be algebraically added to process value of
19
sensor 1, SV1.
The unit of BIAS_1 is the PRIMARY_VALUE_UNIT.
Bias that can be algebraically added to process value of
20
sensor 2, SV2.
The unit of BIAS_2 is the PRIMARY_VALUE_UNIT.
Holds the maximum SECONDARY_VALUE_1. The unit is
28
defined in
SECONDARY_VALUE_1.
Holds the minimum SECONDARY_VALUE_1. The unit is
29
defined in
SECONDARY_VALUE_1.
30
See. MAX_SENSOR_VALUE_1
31
See. MIN_SENSOR_VALUE_1
Description
FF
Process value, function determined by SENSOR_MEAS_
TYPE of SECONDARY_VALUE_1/2.
13
The unit of PRIMARY_VALUE is the PRIMARY_VALUE_
UNIT.
FF Channel 1 Output. PA Channel 280
Process value connected to sensor 1 corrected by
BIAS_1. The unit of SECONDARY_VALUE_1 is the
15
PRIMARY_VALUE_UNIT.
FF Channel 2 Output, PA Channel 282
Process value connected to sensor 2 corrected by
BIAS_2. The unit of SECONDARY_VALUE_2 is the
16
PRIMARY_VALUE_UNIT.
FF Channel 3 Output, PA Channel 283
Internal electronics temperature. The unit of INTERN_
TEMP is the PRIMARY_VALUE_UNIT. If PRIMARY_VALUE_
UNIT is no temperature unit (e.g. mV) INTERN_TEMP is
45
stated in °C.
FF Channel 4 Output, PA Channel 341
Size
RO /
Type Store
byte
R/W
Un-
signed
SRC
1
R/W
8
Float
SRC
4
R/W
Float
SRC
4
R/W
Float
N
4
R/W
Float
N
4
R/W
Float
N
4
R/W
Float
N
4
R/W
Size
RO /
Type Store
byte
R/W
DS-33
D
5
RO
DS-33
D
5
RO
DS-33
D
5
RO
DS-33
D
5
RO
Min. Max. Default
220
0
0
0
0
0
0
Min. Max. Default
0
0
0
0
21