Download Print this page

PR PRetop 5331 Manual

2-wire programmable transmitter

Advertisement

Available languages

Available languages

Quick Links

Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling,
and difference measurement functions for programming
via PReset software.
Ex interfaces
Interfaces
for
analogue
®
signals as well as HART
signals between sensors / I/P
converters / frequency signals and control systems in Ex
zone 0, 1 & 2 and for some modules in zone 20, 21 & 22.
Isolation
Galvanic isolators for analogue and digital
signals as well as HART
®
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Universal
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnosis.
and
digital
5 3 3 1
2 - W i r e P r o g r a m m a b l e
T r a n s m i t t e r
N o . 5 3 3 1 V 1 1 1 - I N ( 0 9 0 9 )
F r o m s e r . n o . 0 6 0 1 6 0 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 13
UK
Page 25
FR
Seite 37
DE

Advertisement

loading

Summary of Contents for PR PRetop 5331

  • Page 1 Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces analogue digital ® signals as well as HART signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 &...
  • Page 2: Table Of Contents

    2-TRÅDS PROGRAMMERBAR TRANSMITTER PRetop 5331 Indholdsfortegnelse Sikkerhedsinstruktion ............EF-overensstemmelseserklæring ........Anvendelse ................. Teknisk karakteristik ............Montage / installation ............Applikationer ..............Bestillingsskema ..............Elektriske specifikationer ........... Tilslutninger ................ 10 Blokdiagram ............... 11 Programmering ..............12 Mekaniske specifikationer ..........12 Montering af følerledninger ..........12 Appendix: FM Installation Drawing No.
  • Page 3: Sikkerhedsinstruktion

    Sikkerhedsinstruktion EF-OVERENSSTEMMELSESERKLÆRING Ex-installation: Som producent erklærer PR electronics A/S For sikker installation af 5331D i eksplosionsfarligt område skal følgende over- Lerbakken 10 holdes. Installation må kun foretages af kvalificeret personale, der er bekendt DK-8410 Rønde med de nationale og internationale love, direktiver og standarder, der gælder for området.
  • Page 4: Anvendelse

    2-trådsinstallation • Kan monteres i DIN form B følerhoved. I ikke-eksplosionsfarlige områder kan i kontrolrum mV til 4...20 mA 5331 monteres på en DIN-skinne med PR-beslag type 8421. • NB: Som Ex-barriere for 5331D anbefaler vi 5104B, 5114B eller 5116B.
  • Page 5: Bestillingsskema

    ≤ ±0,01% af span / °C ≤ ±0,05% af span Alle Max. nulpunktsforskydning (offset) ..... 50% af valgt max. værdi Kabelmodstand pr. leder (max.) ....5 Ω Følerstrøm ........... Nom. 0,2 mA Virkning af følerkabelmodstand (3- / 4-leder) ..........< 0,002 Ω/Ω...
  • Page 6 TC-indgang: EEx- / I.S.-godkendelse - 5331D: KEMA 06ATEX0062 X ........II 1 GD, T80°C...T105°C Min. Max. Min. Type temperatur temperatur span Standard EEx ia IIC T6 / T4 Max. omgivelsestemp. for T1...T4 ....85°C +400°C +1820°C 200°C IEC584 Max. omgivelsestemp. for T5 og T6 ..60°C -100°C +1000°C 50°C...
  • Page 7: Blokdiagram

    BLOKDIAGRAM:...
  • Page 8 Programmering: 2-WIRE PROGRAMMABLE TRANSMITTER • Loop Link er et batteridrevet kommunikationsinterface, der er nødvendigt for programmering af PRetop 5331. PRetop 5331 • Ved programmering henvises til tegningen nedenfor og hjælpefunktionen i PReset programmet. • Loop Link må ikke benyttes til kommunikation med moduler installeret i Ex- område...
  • Page 9: Safety Instructions

    Safety instructions EC DECLARATION OF CONFORMITY Ex installation: As manufacturer PR electronics A/S For a safe installation of 5331D in hazardous area the following must be Lerbakken 10 observed. The module must only be installed by qualified personnel who are DK-8410 Rønde...
  • Page 10: Application

    • For DIN form B sensor head mounting. In non-hazardous areas the 5331 can in control room mV to 4...20 mA be mounted on a DIN rail with the PR fitting type 8421. • NB: As Ex barrier for 5331D we recommend 5401B, 5114B, or 5116B.
  • Page 11: Order

    Order: 5331 Basic values Basic Temperature Input type accuracy coefficient ≤ ±0.2°C ≤ ±0.01°C/°C Ambient Galvanic Type Version temperature isolation ≤ ±0.1 Ω ≤ ±10 mΩ/°C Lin. R ≤ ±10 µV ≤ ±1 µV/°C -40°C…+85°C : 3 1500 VAC : B Volt Standard 5331...
  • Page 12 TC input: EEx / I.S. approval - 5331D: Min. Max. Min. KEMA 06ATEX0062 X ........II 1 GD, T80°C...T105°C Type temperature temperature span Standard EEx ia IIC T6 / T4 Max. amb. temperature for T1...T4 ..... 85°C +400°C +1820°C 200°C IEC584 Max.
  • Page 13: Block Diagram

    BLOCK DIAGRAM:...
  • Page 14: Programming

    Programming: TRANSMETTEUR 2-FILS UNIVERSEL (Pt100/TC) • Loop Link is a communications interface that is needed for programming PRetop 5331. PRetop 5331 • For programming please refer to the drawing below and the help functions in PReset. • Loop link is not approved for communication with modules installed in...
  • Page 15: Consigne De Sécurité

    Le transmetteur doit seulement être installé dans les atmosphères potentiellement EN 50014 : 1997 + A1, A2, EN 50020 : 2002 et explosibles dû à la présence de poussières combustibles quand il est monté EN 50284 : 1999 dans un boîtier métallique DIN B conformément à DIN 43729 assurant un IEC 61241-0 : 2004 et IEC 61241-11 : 2005 degré...
  • Page 16: Application

    4...20 mA • Pour tête de sonde DIN B. En zone non-dangereuse le 5331 peut être monté sur rail DIN avec le support PR type 8421. • N.B. : Comme barrière S.I. pour le 5331D nous recommandons le PR5104B,...
  • Page 17: Spécifications Électriques

    Dynamique du signal de sortie ....16 bit Poids ............50 g Température d’étalonnage ......20...28°C Précision, la plus grande des valeurs générales et de base : Spécifications électriques, entrée : Entrée RTD et entrée résistance linéaire : Valeurs générales Type Valeur min.
  • Page 18 Entrée TC : Approbation EEx / S.I. - 5331D : KEMA 06ATEX0062 X ......... II 1 GD, T80°C...T105°C Température Température Plage Type min. max. min. Standard EEx ia IIC T6 / T4 Température amb. max. (T1...T4) ....85°C +400°C +1820°C 200°C IEC584 Température amb.
  • Page 19: Schéma De Principe

    SCHEMA DE PRINCIPE :...
  • Page 20: Programmation

    UNIVERSALMESSUMFORMER • Loop Link est un kit de programmation permettant de programmer le PRetop 5331. PRetop 5331 • Pour le raccordement du Loop Link, veuillez vous reporter au schéma ci- dessous et à l’aide en ligne du logiciel PReset. • Loop Link ne doit pas être utilisé pour communication avec des modules installés en zone dangereuse.
  • Page 21: Sicherheitsinstruktion

    Sicherheitsinstruktion EG-KONFORMITÄTSERKLÄRUNG Ex-Installation: Als Hersteller bescheinigt PR electronics A/S Für sichere Installation von 5331D in explosionsgefährdeter Umgebung muss Lerbakken 10 folgendes beobachtet werden. Die Installation muss nur von qualifizierten DK-8410 Rønde Personen, die mit den nationalen und internationalen Gesetze, Direktiven und Standards des Gebiets bekannt sind, vorgenommen werden.
  • Page 22: Verwendung

    4...20 mA im Kontrollraum • Für DIN Form B Sensorkopf Montage. Im sicheren Bereich kann der 5331 auf einer DIN- Schiene mittels der PR-Armatur Typ 8421 montiert werden. • NB: Als Ex-Sicherheitsbarriere für 5331D empfehlen wir 5104B, 5114B oder 5116B.
  • Page 23: Elektrische Daten

    Bestellangaben: 5331 Grundwerte Grund- Temperatur- Eingangsart Genauigkeit koeffizient ≤ ±0,2°C ≤ ±0,01°C/°C Umgebungs- Galvanische Version ≤ ±0,1 Ω ≤ ±10 mΩ/°C temperatur Trennung Lin. R ≤ ±10 µV ≤ ±1 µV/°C Volt -40°C…+85°C : 3 1500 VAC : B Standard 5331 CSA, FM &...
  • Page 24 TE-Eingang: EEx- / I.S.-Zulassung - 5331D: KEMA 06ATEX0062 X ......... II 1 GD, T80°C...T105°C Min. Max. Min. Temperatur Temperatur Spanne Norm EEx ia IIC T6 / T4 Max. Umgebungstemp. für T1...T4 ..... 85°C +400°C +1820°C 200°C IEC584 Max. Umgebungstemp. für T5 und T6 ..60°C -100°C +1000°C 50°C...
  • Page 25: Blockdiagramm

    BLOCKDIAGRAMM:...
  • Page 26: Appendix

    Programmierung: APPENDIX • Loop Link ist eine batteriegespeiste Schnittstelle zur Programmierung des PRetop 5331. • Bezüglich Programmierung verweisen wir auf die nachfolgende Zeichnung und die “Hilfe”-Funktion im PReset-Programm. • Loop Link darf nicht zur kommunikation mit Modulen, die in Ex-gefährdeten Bereichen installiert sind, benutz werden.
  • Page 27 The entity concept. Installation Drawing 5300Q502. The Transmitter must be installed according to National Electrical Code (ANSI-NFPA 70). Model 5331C,5331D, 5333C and 5333D When installed in Class II locations the Transmitter shall be installed in an enclosure Non Hazardous Location Hazardous (Classified) Location with a specified ingress protections of IP6X according to IEC60529 and Dust-tight conduit seals must be used.
  • Page 28 CSA Installation Drawing 533XQC03. 5331D, 5333D and 5335D transmitters are intrinsically safe in Zone 0 Group IIC 2. Connection with power supply and barrier built into receiver. or Class I, Division1, Group A,B,C,D when installed according to Installation Output: Standard 4 - 20 mA loop Drawing.
  • Page 29 Subsidiaries PR electronics A/S tilbyder et bredt program af analoge og digi- France tale signalbehandlingsmoduler til industriel automation. Vores PR electronics Sarl Zac du Chêne, Activillage sales@prelectronics.fr kompetenceområder omfatter: Isolation, Displays, Ex-interfaces, 4, allée des Sorbiers tel. +33 (0) 4 72 14 06 07 Temperatur samt Universal-moduler.