9.27 Fuser unit
(1) Release the harness of the fuser unit from the guide of the main frame R ASSY.
(2) While pushing the hook of the connector of the fuser unit, disconnect the connector on
the low voltage power supply PCB ASSY.
Main frame R ASSY
Connector
(Low voltage power
supply PCB ASSY)
(3) Put the connector of the fuser unit through the hole of the main frame R ASSY, and send
it inside.
Connector
(Low voltage power supply PCB ASSY)
Hook
Fig. 3-40
Fig. 3-41
3-53
Guides
Connector (Fuser unit)
Connector (Fuser unit)
Hole
Connector (Fuser unit)
Guide
Confidential