Mitsubishi GOT2000 Series Connection Manual page 483

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

(2) MELSERVO-J2M-P8A
*2
Device name
Servo amplifier request
SP1
(SP)
Operation mode selection
OM0
(OM)
Basic parameter
PRM0
Expansion parameter
PRM1000 to
*1
(PRM)
Status display (ST)
ST0
AL0
AL11
Alarm (AL)
AL200
AL210
AL230
*3
DI0
External input (DI)
External output (DO)
DO0
Forced output of signal pin
(for test operation)
TMO0
(TMO)
*1
Use PRM0 to PRM29 when writing parameters to the servo
amplifier RAM.
PRM1000 to PRM1029 are used when writing parameters to
2
E
PROM of the servo amplifier.
*2
The GOT cannot read or write data from/to consecutive
devices.
*3
Only reading is possible.
POINT
POINT
POINT
Precautions for SP, OM, and TMO devices
(1) For bit devices
Only writing is possible.
[Alternate] of a bit switch cannot be used.
Use [Set], [Reset], and [Momentary] of a bit
switch.
(2) For word devices
Only writing is possible.
Numerical input cannot be used.
When writing, use [Word Set] of a data set switch.
Device
No.
Setting range available
represent
ation
to
SP2
to
OM4
to
PRM29
PRM1029
to
ST2
Decimal
to
AL13
to
AL205
to
AL215
to
AL235
to
DI2
to
DO1
(a) Servo amplifier request
Device name
SP1
Current alarm clear
SP2
Alarm history clear
(b) Operation mode selection
Device name
Normal mode
OM0
(not test operation mode)
Output signal (DO) forced
OM4
output
(c) Basic parameter/expansion parameter
Device name
Serial communication
PRM0, PRM1000
function selection,
alarm history clear
Regenerative brake option
PRM1, PRM1001
selection
PRM2, PRM1002
Function selection 1
PRM3, PRM1003
Analog monitor 1 output
PRM4, PRM1004
Analog monitor 2 output
PRM5, PRM1005
Analog monitor 3 output
PRM6, PRM1006
Analog monitor 1 offset
PRM7, PRM1007
Analog monitor 2 offset
PRM8, PRM1008
Analog monitor 3 offset
PRM9, PRM1009
Function selection 2
Interface unit serial
PRM10, PRM1010
communication station No.
selection
Slot 1 serial communication
PRM11, PRM1011
station No. selection
Slot 2 serial communication
PRM12, PRM1012
station No. selection
Slot 3 serial communication
PRM13, PRM1013
station No. selection
Slot 4 serial communication
PRM14, PRM1014
station No. selection
Slot 5 serial communication
PRM15, PRM1015
station No. selection
Slot 6 serial communication
PRM16, PRM1016
station No. selection
Slot 7 serial communication
PRM17, PRM1017
station No. selection
Slot 8 serial communication
PRM18, PRM1018
station No. selection
PRM19, PRM1019
Parameter write inhibit
Serial communication
PRM20, PRM1020
time-out selection
PRM21 to PRM29
For manufacturer setting
PRM1021 to PRM1029
*2
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
(d) Status display
Device name
ST0
Regenerative load ratio
ST1
Bus voltage
ST2
Peak bus voltage
15. SERVO AMPLIFIER CONNECTION
15.6 Device Range that Can Be Set
Item
Symbol
Item
Symbol
*2
Item
Symbol
*BPS
*REG
*OP1
MD1
MD2
MD3
MO1
MO2
MO3
*OP2
*ISN
*DSN1
*DSM2
*DSM3
*DSN4
*DSN5
*DSN6
*DSN7
*DSN8
*BLK
SIC
Item
Symbol
15 - 19
15