Panasonic DVCPRO50 AJ-D960EG Operating Instructions Manual page 68

Dvcpro50 digital video cassette recorder
Table of Contents

Advertisement

Setup menus
USER menu
<INTERFACE>
No.
200
201
202
203
204
205
206
207
208
209
210
The underline on the setting item denotes the initial setting.
Item
Setting
Superimposed
Superimposed
No.
display
display
PARA RUN
0000
0001
9P SEL
0000
0001
ID SEL
0000
0001
DVCPRO
25P SEL
0000
0001
RS232C SEL 0000
0001
BAUD RATE
0000
0001
0002
0003
0004
0005
DATA
0000
LENGTH
0001
STOP BIT
0000
0001
PARITY
0000
0001
0002
RETURN
0000
ACK
0001
25P STBY
0000
OFF/ON
CMD
0001
68 (E)
DIS
This selects whether two or more VTRs are to be operated in
synchronization.
ENA
0: No operation in synchronization
1: Operation in synchronization
<Note>
When operating two or more VTRs in synchronization, set all
the VTRs to 0001 (ENA).
OFF
This selects whether the 9P connector functions when the
REMOTE/LOCAL switch has been set to REMOTE.
ON
0: Do not function
1: Function
This selects the ID information which is returned to the
OTHER
controller.
0: 20 25H = 525 mode; 21 25H = 625 mode
1: The DVCPRO's original ID (F0 33H = 525 mode; F1 33H =
625 mode) is returned.
OFF
This selects whether the PARALLEL (25P) connector functions
when the REMOTE/LOCAL switch has been set to REMOTE.
ON
0: Does not function
1: Functions
These settings are for selecting whether the RS-232C
OFF
connector is to function when the REMOTE/LOCAL switch is
ON
set to REMOTE.
0: Connector does not function.
1: Connector functions.
300
These settings are for selecting the RS-232C communication
speed (baud rate).
600
1200
2400
4800
9600
7
These settings are for selecting the RS-232C data length.
(Unit: bit)
8
1
These settings are for selecting the RS-232C stop bit length.
(Unit: bit)
2
These settings are for selecting the none, odd or even for the
NON
RS-232C parity bit.
ODD
0: Parity bit is not used.
EVEN
1: An odd number of bits is used for the parity system.
2: An even number of bits is used for the parity system.
These settings are for selecting whether the ACK code is to be
OFF
returned when a command is received from RS-232C.
ON
0: ACK code is not returned.
1: ACK code is returned.
For selecting the method used to detect the STANDBY
COMMAND signal input at the PARALLEL (25P) connector.
ON
0: Each time active signals are detected, the STANDBY ON or
STANDBY OFF mode is selected alternately.
1: When active signals are detected in the STANDBY OFF
mode, the unit is transferred to the STANDBY ON mode.
Nothing happens if they are detected during an operation in
the STANDBY ON mode.
Description