Table of AUTO OFF Error messages

Counter display
CAP ROTATE TOO
SLOW
CAP TENSION ERROR
DEW
DRUM ROTATE TOO
FAST
DRUM ROTATE TOO
SLOW
DRUM TORQUE
ERROR
E-FF
FRONT LOAD ERROR
FRONT LOAD MOTOR
LOADING MOTOR
Monitor display
If the capstan motor speed is abnormally low, the
CAP ROTA TOO
AUTO OFF lamp lights, and the message display
SLOW
flashes.
If an abnormal tension at the supply side is detected
CAP TENSION ERROR
in the capstan mode, the AUTO OFF lamp lights, and
the message display flashes.
If condensation is detected, the AUTO OFF lamp
DEW
lights, the message display flashes, and the VTR is
transferred to the eject mode. After the tape is
ejected, the drum rotates in order to eliminate the
condensation.
When the condensation has been eliminated, the
AUTO OFF lamp and message display go off, and the
VTR can be used.
<Notes>
If the cylinder motor speed is abnormally high, the
DRUM ROTA TOO
AUTO OFF lamp lights, and the message display
FAST
flashes.
If the cylinder motor speed is abnormally low, the
DRUM ROTA TOO
AUTO OFF lamp lights, and the message display
SLOW
flashes.
When it has been detected that the cylinder motor is
DRUM TORQUE
subject to an abnormal torque, the AUTO OFF lamp
ERROR
lights, and the message display flashes.
If the tape start and tape end are detected simulta-
E-FF
neously either during or after loading, the AUTO OFF
lamp lights, and the message display flashes.
The AUTO OFF lamp lights and the message display
FRONT LOAD ERROR
flashes when the take-up reel has been rotating idly
for a fixed period of time while the start/end
processing operation during loading (half position) is
being performed.
If the cassette does not move up even when 6
FRONT LOAD MOTOR
seconds have elapsed since the VTR was transferred
to the eject mode, the AUTO OFF lamp lights, and the
message display flashes.
<Note>
If the cassette does not move down inside the
machine even when 6 seconds have elapsed since
the cassette was inserted, the VTR is transferred to
the eject mode.
When the unloading operation is not completed within
LOADING MOTOR
6 seconds, the AUTO OFF lamp lights, and the
message display flashes.
<Note>
When the loading operation is not completed within 6
seconds, the VTR is transferred to the eject (unload-
ing) mode.
Description
1)
If condensation is detected in the eject mode, the
drum starts rotating as soon as it is detected.
2)
If condensation is detected when the cassette has
been inserted, the drum rotation is stopped, and
after the tape is ejected, the drum starts rotating.
104 (E)
VTR operation
(Restart condition)
STOP
(POWER OFF ON)
STOP
(POWER OFF ON)
EJECT
(Normal operation
resumed after
condensation is
eliminated)
STOP
(POWER OFF ON)
STOP
(POWER OFF ON)
STOP
(POWER OFF ON)
STOP
(POWER OFF ON)
STOP
(POWER OFF ON)
STOP
(POWER OFF ON)
STOP
(POWER OFF ON)

Hide quick links: