Description
P1047[0] MOP ramp-up time of the RFG
P1048[0] MOP ramp-down time of the RFG
P1074[0] BI: Disable additional setpoint
P2010[0] USS/MODBUS baudrate
P2011[0] USS address
P2012[0] USS PZD length
P2013[0] USS PKW length
P2014[0] USS/MODBUS telegram off time
P2021[0] MODBUS address
P2022[0] MODBUS reply timeout
P2023[0] RS485 protocol selection
P2034
MODBUS parity on RS485
P2035
MODBUS stop bits on RS485
P2200[0] Enable PID controller
P2216[0] Fixed PID setpoint mode
P2220[0] BI: Fixed PID setpoint select bit 0
P2221[0] BI: Fixed PID setpoint select bit 1
P2222[0] BI: Fixed PID setpoint select bit 2
P2253[0] CI: PID setpoint
P2264[0] CI: PID feedback
3.2.4

Setting application macros

Functionality
This menu defines certain common applications. Each application macro provides a set of parameter settings for a specific
application. After you select an application macro, the corresponding settings are applied to the inverter to simplify the
commissioning process.
Application macro specific parameters
Parameter Description
P1080[0]
Minimum frequency
P1300[0]
Control mode
P1110[0]
BI: Inhibit negative
frequency setpoint
P1200[0]
Flying start
P1210[0]
Automatic restart
P1120[0]
Ramp-up time
P1121[0]
Ramp-down time
P1312[0]
Starting boost
P1311[0]
Acceleration boost
P1310[0]
Continuous boost
SINAMICS V20 Inverter
A5E37281078-003, 05/2016
Default values for connection macros (Cn...)
001
002
003
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Factory
Default for application macro
default
AP010 AP020 AP021 AP030
0
15
20
0
7
7
0
1
-
0
-
2
1
2
2
10
10
10
10
10
20
0
-
-
0
-
-
50
-
004
005
006
-
-
10
-
-
10
-
1025.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Remarks
-
-
Inverter running at a lower speed inhibited
0
1
=7: Quadratic V/f
=0: Linear V/f
=1: V/f with FCC
-
-
Reverse rotation inhibited
-
-
Search for the speed of the running motor
with a heavy inertia load so that the motor
runs up to the setpoint
-
-
Restart after mains blackout
10
5
Ramp-up time from zero to maximum fre-
quency
10
5
Ramp-down time from maximum frequency
to zero
30
30
Boost only effective when accelerating for
the first time (standstill)
0
-
Boost only effective when accelerating or
braking
50
-
Additional boost over the complete fre-
quency range
007
008
009
010
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8
-
-
-
1
-
-
-
2
-
-
-
127
-
-
-
500
-
-
-
-
-
-
-
-
-
-
-
1
-
-
-
-
-
-
-
-
-
1
1
-
-
-
1
-
-
-
722.1
-
-
-
722.2
-
-
-
722.3
-
-
755.0
2224
-
-
755.1
755.1
-
011
-
-
-
6
-
-
-
100
1
1000
2
2
1
-
-
-
-
-
-
-
21