Parameter
Description
P1005[0...2]
Fixed frequency 5 - 14 [Hz]
-
P1014[0...2]
P1015[0...2]
Fixed frequency 15 [Hz]
P1016[0...2]
Fixed frequency mode
1
Direct selection
2
Binary selection
P1031[0...2]
MOP mode
P1032
Inhibit reverse direction of MOP
0
Reverse direction is allowed
1
Reverse direction inhibited
P1040[0...2]
Setpoint of the MOP [Hz]
P1047[0...2]
MOP ramp-up time of the RFG [s]
P1048[0...2]
MOP ramp-down time of the RFG [s]
r1050
CO: Actual output freq. of the MOP [Hz]
P1058[0...2]
JOG frequency [Hz]
P1059[0...2]
JOG frequency left [Hz]
P1060[0...2]
JOG ramp-up time [s]
P1061[0...2]
JOG ramp-down time [s]
P1080[0...2]
Minimum frequency [Hz]
P1082[0...2]
Maximum frequency [Hz]
P1120[0...2]
Ramp-up time [s]
P1121[0...2]
Ramp-down time [s]
P1130[0...2]
Ramp-up initial rounding time [s]
P1131[0...2]
Ramp-up final rounding time [s]
P1132[0...2]
Ramp-down initial rounding time [s]
P1133[0...2]
Ramp-down final rounding time [s]
P1134[0...2]
Rounding type
0
Continuous smoothing
1
Discontinuous smoothing
P1135[0...2]
OFF3 ramp-down time [s]
P1200
Flying start
0
Flying start disabled
1
Flying start always active; searches in both directions
2
Flying start active after power on, fault, OFF2; searches in both directions
3
Flying start active after fault, OFF2; searches in both directions
4
Flying start always active; searches in direction of setpoint only
5
Flying start active after power on, fault, OFF2; searches in direction of setpoint only
6
Flying start active after fault, OFF2; searches in direction of setpoint only
P1202[0...2]
Search rate: flying start [%]
P1203[0...2]
Search rate: flying start [%]
r1204
Status word: flying start V/f
Bit Signal
00 Voltage reduced
02 Voltage reduced
04 Current less threshold
07 Speed could not be found
P1210
Automatic restart
0
Disabled
SINAMICS V20 Inverter
A5E37281078-003, 05/2016
Range
Factory default
-550.00 - 550.00
0.00
-550.00 - 550.00
0.00
1 - 2
1
0 - 3
1
0 - 1
1
-550.00 - 550.00
5.00
0.00 - 1000.00
10.00
0.00 - 1000.0
10.00
-
-
0.00 - 550.00
5.00
0.00 - 550.00
5.00
0.00 - 650.00
10.00
0.00 - 650.00
10.00
0.00 - 550.00
0.00
0.00 - 550.00
50.00
0.00 - 650.00
10.00
0.00 - 650.00
10.00
0.00 - 40.00
0.00
0.00 - 40.00
0.00
0.00 - 40.00
0.00
0.00 - 40.00
0.00
0 - 1
0
0.00 - 650.00
5.00
0 - 6
0
10 - 200
100
10 - 500
100
-
-
1 signal
Bit
Yes
01
Yes
03
Yes
05
Yes
0 - 8
1
Acc.
level
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
2
2
2
2
2
2
2
3
3
4