Siemens SIMOREG DC-MASTER Operating Instructions Manual page 43

Converter commutation protector
Table of Contents

Advertisement

12.2010
PNU
Description
n572
Rated current of the SIMOREG CCP
(2572)
Rated current of the SIMOREG CCP stamped on the rating plate
n574
State of the SIMOREG CCP
(2574)
Display at the operator panel (PMU):
Segment lit or bit = 1: significance specified below applies
Segment dark or bit = 0:
Segment or bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Note:
This parameter has the same bit assignment as connector K0574.
n575
Display of the I2t value
(2575)
of the voltage limitingchoppers 1 of the SIMOREG CCP
n576
Display of the I2t value
(2576)
of the voltage limitingchoppers 2 of the SIMOREG CCP
Siemens AG
6RX1700-0DD74
SIMOREG DC-MASTER Converter Commutation Protector
15
14
13
12
11
10
9
6
4
7
5
3
2
1
significance specified below does not apply
Voltage at U, V, W is OK
Voltage at C – D greater than +100 V
Voltage at C – D less than -100 V
The quenching capacitors have reached the setpoint
voltage
Turn-off operation running
Connection between parallel SIMOREG CCP OK
-
-
Parallel interface connected at CCP
I2t value of voltage limiting chopper 1 is too high
I2t value of voltage limiting chopper 2 is too high
Contents of the memory of the technical data of the
SIMOREG CCP (MLFB, rated values, serial number)
valid
Pre-charging of the chopper capacitors completed
-
-
-
Value range
[dimension]
Graduation
0.0 to 6553.5
[from SW 2.1 and higher]
[A]
0.1A
[from SW 2.2 and higher]
8
0
[from SW 2.1]
0 to 100
[%]
1 %
[from SW 2.1]
0 to 100
[%]
1 %
Operating Instructions
Commissioning
No. of
See/
indices
change
Factory
(Access /
setting (FS)
state)
Type
Ind: None
P052 = 3
Type: O2
Ind: None
P052 = 3
Type: V2
Ind: None
P052 = 3
Type: O2
Ind: None
P052 = 3
Type: O2
43