Trigger System - HP 54600B User, Installation And Service Manual

Hide thumbs Also See for 54600B:
Table of Contents

Advertisement

Performance Characteristics

Trigger System

Trigger System
Internal trigger
Sensitivity
HP 54600B dc to 25 MHz
HP 54601B dc to 25 MHz
HP 54602B dc to 25 MHz
HP 54603B dc to 25 MHz
Sources Channels 1, 2, 3, 4, and line on HP 54601B & HP 54602B
Coupling ac, dc, LF reject, HF reject, and noise reject
Modes Auto, Autolevel, Normal, Single, and TV
TV triggering Available on channels 1 and 2 only
TV line and field 0.5 division of composite sync for stable display
Holdoff Adjustable from 200 ns to ≈13 s
5–6
1
dc to 100 MHz
dc to 100 MHz
25 MHz to 100 MHz 1.5 div or 3 mV (1, 2, or 5 mV/div)
dc to 150 MHz
dc to 250 MHz
dc to 60 MHz
Channels 1, 2, line, and external on HP 54600B and HP 54603B
LF reject and HF reject −3 dB at ≈50 kHz
0.35 div or 3.5 mV
1 div or 10 mV
0.35 div or 3.5 mV
1 div or 10 mV
0.35 div or 3.5 mV (>5 mV/div)
1.0 div or 2 mV (1, 2, or 5 mV/div)
1 div or 10 mV (chan 1&2)(>5 mV/div)
1 div or 100 mV (chan 3&4)
0.35 div or 3.5 mV
1 div or 10 mV

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp 54601bHp 54602bHp 54603b

Table of Contents