Technical specifications

The RackSwitch technical specifications are described in the following sections.

Physical characteristics

The physical characteristics of the RackSwitch are listed in the following table.

Environmental specifications

The environmental specifications for the RackSwitch are listed in the following table.

Power specifications

the power specifications for the RackSwitch are listed in the following table.
Table 12. Physical characteristics
Specification
Dimensions (H x W x D)
Weight
Table 13. Environmental specifications
Specification
Temperature, ambient operating
Temperature (fan failure), operating
Temperature, storage
Relative humidity (non-condensing),
operating
Relative humidity (non-condensing), storage
Altitude, operating
Altitude, storage
Acoustic noise
Heat dissipation
Table 14. AC power specifications
Specification
Number of power supplies
AC-input frequency (universal)
AC-input voltage (universal)
AC inrush current
AC-input current (typical)
AC-input current (maximum)
Power supply rated output power
System power dissipation (typical)
System power dissipation (maximum)
Physical characteristics
4.4 x 43.9 x 51.3 cm.
(1.73 x 17.3 x 20.2 in.)
10.5 kg. (23 lb) (maximum)
Measurement
0°C to +40°C (32° to 104°F)
0°C to +35°C (32° to 95°F)
-40°C to +85°C (-40° to 185°F)
10 to 90%
10 to 90%
1,800 m (6,000 feet)
12,190 m (40,000 feet)
Less than 65dB
1127 BTU/hour (typical)
1280 BTU/hour (maximum)
Measurement
2 (1+1 load sharing/redundant)
50 - 60 Hz
100 - 240 VAC
15 A
2.75 A (RMS) @ 120 V
1.435 A (RMS) @ 230 V
3.125 A (RMS) @ 120 V
1.630 A (RMS) @ 230 V
450 W each
330 W
375 W