Configuring Vital Product Data After A Switch Replacement - IBM G8000 Installation Manual

Hide thumbs Also See for G8000:
Table of Contents

Advertisement

Configuring Vital Product Data after a switch replacement

After you replace a RackSwitch, you must update the new switch with the VPD of
the RackSwitch being removed to avoid losing the licensed electronic entitlement
data of the RackSwitch. The VPD includes the model and serial number of the
switch. For more information on locating the VPD, see "Before installing the
RackSwitch" on page 15.
To update the VPD on a new switch, complete the following steps.
1. Log in to the switch and in the CLI mode, type
2. At the Password prompt, enter the switch password, and press Enter. The
3. In the main menu, enter the machine-type model (MTM) number for the
4. Enter the serial number for the replacement switch. For example:
5. Reset the switch using the following command:
6. When prompted to confirm the reset, enter y. The switch reboots.
7. After the switch reboots, at the command prompt, verify that the VPD
RS G8000>ibmnos
default password is admin.
replacement switch. For example:
/boot/mtm 1455-64C
where 1455-64C is the MTM of the unit that is being replaced
/boot/esn 1000001
where 1000001 is the serial number of the unit that is being replaced.
/boot/reset
information is correct by issuing the show sys-info command using the ISCLI
interface or the /info/sys/general command using MenuCLI interface.
ISCLI interface output example:
show sys-info
Chapter 3. Removing and replacing the RackSwitch and components