Chapter 5. Technical Specifications
These are the technical specifications for installing and using the SAN48C-6 switch.
Switch Specifications
The following table lists the environmental specifications for the IBM SAN48C-6 switch:
Table 3. Environmental Specifications for the IBM SAN48C-6SAN48C-6 Switch
Description
Temperature, ambient operating
Temperature, ambient nonoperating and storage
Humidity (RH), ambient (noncondensing) operating
Humidity (RH), ambient (noncondensing)
nonoperating and storage
Altitude, operating
The following table lists the physical specifications for the IBM SAN48C-6SAN48C-6 switch.
Table 4. Physical Specifications for the IBM SAN48C-6SAN48C-6 Switch
Description
Dimensions (HxWxD)
Rack Space
Weight
Fan Dimensions (WxH)
Fan Slots Opening Dimensions (WxH)
Power Supply
©
Copyright IBM Corp. 2021
Specification
32 to 104°F (0 to 40°C)
-40 to 158°F (-40 to 70°C)
10 to 90%
10 to 95%
-197 to 6500 ft (-60 to 2000 m)
Specification
1.72 x 17.3 x 22.3 in. (4.37 x 43.94 x 56.64 cm)
excluding PSU and fan module handles
Chassis requires 1 RU (1.75 in. or 4.45 cm)
18.73 lb (8.5 kg)
1.575 x 1.575 in. (4.0 x 4.0 cm)
1.614 x 1.602 in. (4.09 x 4.06 cm)
• 650-W AC, port-side exhaust variant (up to 2 per
switch)
• 650-W AC, port-side intake variant (up to 2 per
switch)
• AC input—100 to 240 V AC (10% range)
• Frequency—50 to 60 Hz (nominal)