Status LEDs for the QSFP+ ports are described in the following table. When the
port is 40 GbE mode, only the first LED applies. When the port is in 10 GbE mode,
each LED provides status for its corresponding 10 GbE port, as noted in the
following table.
Technical specifications
The RackSwitch technical specifications are described in the following sections.
Physical characteristics
The physical characteristics of the RackSwitch are listed in the following table.
Environmental specifications
The environmental specifications for the RackSwitch are listed in the following table.
Power specifications
The power specifications for the RackSwitch are listed in the following table.
10
IBM System Networking RackSwitch G8316, Type 8036 and Type 1611-16E: Installation Guide
Table 8. SFP+ LEDs status
Steady green
Valid link
Table 9. Physical characteristics
Specification
Dimensions (H x W x D)
Weight
Table 10. Environmental specifications
Specification
Temperature, ambient operating
Temperature (fan failure), operating
Temperature, storage
Relative humidity (non-condensing),
operating
Relative humidity (non-condensing), storage
Altitude, operating
Altitude, storage
Acoustic noise
Heat dissipation
Table 11. AC power specifications
Specification
Number of power supplies
AC-input frequency (universal)
AC-input voltage (universal)
Flash green
Activity
Physical characteristics
4.4 x 43.9 x 51.3 cm.
(1.73 x 17.3 x 20.2 in.)
10.5 kg. (23 lb) (maximum)
Measurement
0°C to +40°C (32° to 104°F)
0°C to +35°C (32° to 95°F)
-40°C to +85°C (-40° to 185°F)
10 to 90%
10 to 90%
1,800 m (6,000 feet)
12,190 m (40,000 feet)
Less than 65dB
955 BTU/hour (typical)
1262 BTU/hour (maximum)
Measurement
2 (1+1 load sharing/redundant)
50 - 60 Hz
100-240 VAC
Off
No Link