Sony PDW-850 Operation Manual page 76

Disc camcorder
Hide thumbs Also See for PDW-850:
Table of Contents

Advertisement

power off, clips are reconstructed on the basis of
markers recorded on the disc when the disc is
loaded in this unit. Therefore, processing takes
longer than for a quick salvage (about 30 seconds,
although it depends on the state of the disc).
Proceed as follows to perform a full salvage.
1
Insert the disc on which recording did
not end normally.
The following salvage message appears.
SALVAGE
TO RECORD ON THE
DISC, IT IS NECESSARY
TO EXECUTE SALVAGE.
SALVAGE OK?
YES
2
Turn the MENU knob to move b to
"YES", and press the MENU knob.
Salvage processing starts, and the message
"EXECUTING" appears.
A results message appears when the
processing finishes.
• If the salvage succeeded, the message
"COMPLETED" appears.
• If the salvage failed, the message
"INCOMPLETED" appears. Clips for
which recording did not end normally are
lost.
To exit without salvaging
Select NO in step 1 to exit without performing
salvage processing.
However, the status of the disc does not change.
Salvage is still required to recover the clips for
which recording did not end normally. The
salvage message will appear again when that disc
is inserted again, or when the camcorder is
powered on again.
Notes
• If salvage processing is not done, sections which were
recorded normally can be played back, but no new
recording can be done on the disc.
• Full salvage of discs recorded by this camcorder can be
performed with the PDW-F1600, PDW-HD1500,
PDW-F800, PDW-700, PDW-740, or PDW-HR1. Full
salvage cannot be performed with any other XDCAM
device. The following message may appear when you
insert a disc that was not recorded normally. The
"XXXX" in the message is a code for XDCAM
76
Handling Discs
NO
devices that can salvage the disc. Refer to the table
below and use one of the indicated devices to salvage
the disc.
SALVAGE
DISC CANNOT BE
RECORDED.
FORMAT DISC OR CONTACT
SERVICE TO RUN CLIP
SALVAGE PROGRAM.
(XXXX)
PUSH ESCAPE SWITCH
OR ROTARY ENCODER.
Code (XXXX) Model name
0002
PDW-1500/530/510/R1
PDW-F70/F350/F330
0200
PDW-F70/F350/F330 (Version
1.9 or higher)
PDW-F75/F355/F335
a)
PDW-HD1500/HR1/700/740
0300
a)
PDW-HD1500/700/740
0301
(Version 1.5 or higher)
PDW-F1600/F800
a) Does not appear on this unit.
To cancel the message and return to normal
operation, exchange the disc for a usable disc
and flick the CANCEL/PRST/ESCAPE switch
to the ESCAPE side, or press the MENU knob.