-1 Fuser Fan Error (Error 127)
• Is the exhaust fan rotating?
• Yes
Replace the main board.
• No
Is the CN2 connector of the high-voltage power supply unit
connected to the board properly?
•No
Connect the CN2 connector appropriately.
• Yes
Replace the exhaust fan or main board.
-2 Drum Fan Error (Error 128)
• Is the drum fan rotating?
• Yes
Replace the main board.
• No
Is the DFAN1 connector of the main board connected to the
board properly?
•No
Connect the DFAN1 connector appropriately.
• Yes
Replace the drum fan or main board.
-3 Power supply unit Fan Error (Error 122)
• Is the power supply unit fan rotating?
• Yes
Replace the main board.
• No
Is the PWFAN2 connector of the main board connected to the
board properly?
•No
Connect the PWFAN2 connector appropriately.
• Yes
Replace the power supply unit fan or main board.
2. Procedures for Repairing