Display
Cause
SERVICE CALL
Ambient
Is the cable from the CU/PU
123:ERROR
humidity
board to the toner sensor
error or non
board connected properly?
connection
of humidity
sensor
SERVICE CALL
Ambient
Is the cable from the CU/PU
124:ERROR
temperature
board to the toner sensor
error
board connected properly?
POWER OFF
Sensor Dewed
AND WAIT FOR A
Error
WHILE
126:CONDENSING
ERROR
SERVICE CALL
An error of
Is the fan's connector
127:ERROR
exhaust fan of
properly connected?
the Fuser
Does the error occur again?
SERVICE CALL
Image drum
Is the connector of the fan
128:ERROR 05
fan error
connected properly?
Does the error occur again?
SERVICE CALL
LED head
Is the LED head installed
134:ERROR
detection
properly?
error (134=K)
Is the LED head fuse
broken?
Does the error occur again?
SERVICE CALL
Image drum
Is the image drum unit
153:ERROR
unit fuse-cut
installed properly?
error
Does the error occur again?
Is the SFP recovered by
replacing the toner sensor
board.
Error details
Measure
No
Re-connect it properly.
Yes
Replace the toner
sensor board.
No
Re-connect it properly.
Yes
Replace the toner
sensor board.
No
Connect properly.
Yes
Replace the fan's
motor.
No
Replace the PU board.
No
Re-connect it properly.
Yes
Replace the fan motor.
No
Replace the CU/PU
board.
No
Install the LED head
unit.
Yes
Check the LED head
fuse.
Yes
Check the fuse.
Turn off and on the
No
SFP.
Yes
Replace the LED head
unit.
No
Re-install it.
Yes
Turn off and on the
SFP.
Yes
Be sure of the cable
connection from the
CU/PU board to the
toner sensor board,
and then replace the
toner sensor board.
No
Replace the CU/PU
board.
Display
Cause
SERVICE CALL
Toner sensor
Is the toner cartridge
163:ERROR
detection
installed?
error (163=K).
Is the toner slide shutter set?
This error
does not
occur with
the SFP in
the factory
shipped
configuration.
SERVICE CALL
A fuser
170:ERROR
thermistor
171:ERROR
short or open
Does the error occur again?
circuit was
detected.
SERVICE CALL
A fuser
172:ERROR
thermistor
173:ERROR
temperature
Does the error occur again?
error (high
Does the error occur again?
or low
temperature)
was detected.
SERVICE CALL
Option unit I/F
182:ERROR
error
Does the error occur again?
Does the error occur again?
POWER OFF/ON
System
190:ERROR
memory
Does the error occur again?
overflow
POWER OFF/ON
CU program
Invalid processing was
203:ERORR *
error (203
performed with a CU
204:ERORR
to 214 do
program.
207:ERORR
not occur in
208:ERORR
general use of
213:ERORR
the SFP)
214:ERORR
POWER OFF/ON
Custom
Custom Media Type table
209:DOWNLOAD
Media
downloading failed.
ERROR
Type table
downloading
failure
2. Procedures for Repairing
Error details
Measure
No
Install the toner
cartridge.
No
Turn it to the fixed
position. Turn off and
on the SFP.
Yes
Replace the toner
sensor assembly.
Turn off and on the
SFP.
Yes
Replace the fuser unit.
Turn off and on the
SFP.
Yes
Replace the fuser unit.
Yes
Replace the low-
voltage power supply,
and then replace the
CU/PU board when
the error occurs again.
Turn off and on the SFP.
Yes
Be sure of connector
connection.
Yes
Replace the option
unit.
Turn off and on the SFP.
Yes
Replace the CU/PU
board.
Replace the CU/PU
board.
Turn off and on the
SFP, and then re-
download it (In general
use of the SFP, this
downloading is not
performed and this
error does not occur).