At+Sttc; At+Domain; At+Fudlx - Jinan USR IOT Technology USR-WIFI232-A2 User Manual

Table of Contents

Advertisement

If you want to keep the Ethernet port open,please use the AT+FEPHY=on.
Close module's Ethernet port function can reduce the power consumption. The default setting for
USR-WIFI232-A/B/C is close Ethernet port function.
Use AT + FVEW = disable/enable, so you can set the modules work in LAN port (disable) or wan port
(enable), the directive restore factory Settings to take effect.
4.13.2.2.33

AT+STTC

Function: Enable/Disable STA port scan function
Format:
Query Operation
AT+STTC<CR>
+ok=<sta><CR>< LF ><CR>< LF >
Set Operation
AT+STTC=<on/off><CR>
+ok<CR><LF><CR><LF>
Parameters:
Sta: when query, this value feedback
4.13.2.2.34

AT+DOMAIN

Function: Set/Query domain of module webpage;
Format
Query Operation
AT+DOMAIN<CR>
+ok=<domian><CR><LF><CR><LF>
Set Operation
AT+DOMAIN=<domain><CR>
+ok<CR><LF><CR><LF>
Parameters:
4.13.2.2.35

AT+FUDLX

Function: Enable/Disable 485 function;
Format:
Query Operation
AT+FUDLX<CR>
+ok=<on/off><CR><LF><CR><LF>
Set Operation
AT+FUDLX=<on/off><CR>
+ok<CR><LF><CR><LF>
Parameters:
On/off: Enable or Disable 485 function
Jinan USR IOT Technology Limited
USR-WIFI232-A2 User Manual
On: Open Ethernet port function;
On: Enable STA port scan function
Off: Disable STA port scan function
domain: domain to access to module webpage
On, enable 485 function;
Off, disable 485 function;
Page 60 of 76
http://www.usriot.com
tec@usr.cn

Advertisement