Ethernet Interface Communication; Usr-Wifi232-A2 Ethernet Interface Networking (As Ap) - Jinan USR IOT Technology USR-WIFI232-A2 User Manual

Table of Contents

Advertisement

AP+STA mode need serial AT command to enable as follows:
AT+FAPSTA=on, Enable AP+STA mode;
Then, when you configure module works as STA mode, it's AP interface still active;
AP+STA Mode Notes:
When user enable
router(AP),
or STA port will have to scan the AP frequently ,which will affect AP port function and may cause
some date loss.
So ,if user confirm STA port can't connect with AP at some time,user can disable the STA scan
through the following command:
AT+STTC=on/off,on:Scan AP;off:No Scan AP.
After re-start module,this command not saved;
AT+FSTTC=on/off;
This command is saved after re-staring the module;

4.4 Ethernet Interface Communication

USR-WIFI232-A2 module provides one 100M Ethernet interface. With this Ethernet interface,
user can easily realize the three interface (WiFi, UART, and Ethernet) intercommunication and
networking. USR-WIFI232-A2 module can configured as Bridge Mode or Router Mode base on
different networking technology.
Notes: As the Ethernet mode will increase additional consumption, so it is default closed. If you
need this function, pls use AT+FEPHY=on to open it and RELD can't change this. For different
application, USR-WIFI232-610 need version switch via commands (such as following description
of
N-ver and Z-ver). With command AT+FVER=n to switch to N-ver and with command
AT+FVER=z to switch to Z-ver.

4.4.1 USR-WIFI232-A2 Ethernet Interface Networking (As AP)

Jinan USR IOT Technology Limited
USR-WIFI232-A2 User Manual
AT+STA function,the STA port need to keep connected with other
Page 26 of 76
http://www.usriot.com
tec@usr.cn

Advertisement

Table of Contents
loading