Error Correction

Take the following corrective solutions when errors occur.
Error
LCD
Condition
description
display
over-
Load current of switch
current
output is more than 80 mA.
error
Pressure is applied during the
zero out operation as follows:
When the switch for positive
pressure is used: ±0.071 MPa
or more.
When the switch positive
Residual
pressure is used:
pressure
±7.1 kPa or more.
error
After displaying for 3 seconds,
it will return to the measuring
mode. Due to the individual
product difference, the setting
range varies ±10% F.S.
Supply pressure exceeds
the maximum regulating
pressure.
Applied
pressure
Supply pressure is below
error
the minimum regulating
pressure.
Internal data error
Internal data error
System
error
Internal data error
Internal data error
High Precision,
PRESSURE
OUT
SET

Example of Internal Circuit and Wiring

-25
NPN open collector output
Solution
Maximum 30 V, 80 mA
Residual voltage:
Shut off the power
1 V or less
supply. After eliminating
the output factor that
caused the excess
current, turn the power
supply back on.
-26
Analog output type
1 to 5 V (±2.5% F.S.)
Bring the pressure
Output impedance:
back to atmospheric
pressure and try
1 kΩ
using the zero out
function.
-28
Analog output type
Reduce/Increase
supply pressure to
4 to 20 mA (±2.5% F.S.)
Maximum load impedance:
within the regulating
pressure range.
Power supply voltage 12 V: 300 Ω
Power supply voltage 24 V: 600 Ω
Minimum load impedance: 50 Ω
-65
PNP open collector
Shut off the power
Maximum 80 mA
supply. Turn the
power supply back
on.
If the power should
not come back on,
please contact SMC
for an inspection.
ZSE30/ISE30
Series
LCD display
Displays the current pressure
condition,
setting
conditions, selected display unit,
MPa
and error codes. A display color
type can be selected from either a
single color display with red or
green, or 2-color display in which
green and red are switched
according to the output.
DOWN button
Use this button to change the
mode or decrease the ON/OFF
set value. It also allows you to
switch to the bottom value display
mode.
mode
ZSE„
ISE„
PSE
Z
SE3
I
PS
Z
SE
I
ZSP
ISA2
IS„
ZSM
PF2„
Brown DC(+)
IF„
Load
+
12
Data
Black OUT
to
24 VDC
Blue DC(–)
Brown DC(+)
Black OUT
+
12
(Analog output)
to
Load
24 VDC
Blue DC(–)
Brown DC(+)
Black OUT
12
+
(Analog output)
to
24 VDC
Load
Blue DC(–)
Brown DC(+)
+
12
to
Black OUT
24 VDC
Load
Blue DC(–)
16-2-9
1
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ise30 series

Table of Contents