ZSE30A
Series
Internal Circuits and Wiring Examples
(
)
Z/ISE30A
F
N
NPN (1 output)
Max. 28 V, 80 mA
Residual voltage 1 V or less
A
NPN (2 outputs)
Brown DC (+)
Black OUT1
White OUT2
FUNC
Blue DC (–)
Max. 28 V, 80 mA
Residual voltage 1 V or less
∗ The FUNC terminal is connected using a dedicated lead wire (ZS-38-5L or ZS-38-U) when the copy function is used. (Refer to "Copy function" on page 10.)
4
(
)
F
/ISE30A
Output
Brown DC (+)
Load
+
12 to
Black OUT
24 VDC
FUNC
Blue DC (–)
Load
Load
+
12 to
24 VDC
P
PNP (1 output)
Max. 80 mA
Residual voltage 1 V or less
B
PNP (2 outputs)
Brown DC (+)
Black OUT1
White OUT2
FUNC
Blue DC (–)
Max. 80 mA
Residual voltage 1 V or less
Brown DC (+)
+
12 to
Black OUT
24 VDC
Load
FUNC
Blue DC (–)
Load
+
12 to
24 VDC
Load