Caution
Set the pressure within the rated pressure range.
The set pressure range is the range of pressure that is possible in setting.
The rated pressure range is the range of pressure that satisfies the specifications (accuracy, linearity, etc.) on the switch.
Although it is possible to set a value outside the rated pressure range, the specifications will not be guaranteed even if the value stays within
the set pressure range.
Switch
For
–101 kPa
vacuum
ZSE30A
–105 kPa
pressure
For
–100 kPa
com-
ZSE30AF
pound
–105 kPa
pressure
For
–100 kPa
positive
ISE30A
–105 kPa
pressure
(–0.105 MPa)
(
ZSE30A
F
Set Pressure Range and Rated Pressure Range
–100 kPa
0
0
10 kPa
)
/ISE30A
Pressure range
100 kPa
500 kPa
100 kPa
105 kPa
1 MPa
1 MPa
1.05 MPa
Rated pressure range of switch
Set pressure range of switch