Resetting the Amplifier to Factory Defaults

If for any reason you need to set the amplifier back to its factory default settings,
there are three levels of reset available. These are performed using either the
rear panel reset switch or the internal reset link. The internal reset link's location
is described overleaf.
The following settings are returned to default values using this method:
Mode: Stereo;
Mutes: OFF;
Digital gain controls: 0dB;
Power on Delay Time: 5 seconds;
GP Output: A/P Monitor;
GP Relay: Follows G/P Out;
GP Input: Disabled;
Temperature Warning: 95°C;
Amplifier Name: "Amplifier Network Name Has Not Been Set!";
Channel Names: A = "Output Channel A", B = "Output Channel B"
Load monitoring is disabled and impedance alarms are set to 0.
The internal user reset is performed by moving the link as explained overleaf.
Amplifier Operator's Manual
The external user reset is performed by holding
in the reset switch on the rear of the amplifier
whilst powering it up. The "POWER" and "BRG"
LEDs will alternately flash for a 3 seconds to
show the default settings have been loaded.