Dual Channel Amps Internal Reset

After removing the lid and with the rear panel facing you, locate the input circuit
board as shown below – it is attached to the input and RS485 XLR connectors.
Find the link as marked by the arrow, and move it as shown to reset.
SAFETY WARNING
Removing the lid will expose you to potentially dangerous voltages!
Disconnect the amplifier from the mains supply and do not touch any
heatsinks as they may still be at a high potential!
Next, turn the amplifier back on – if the link is in the reset position, the "POWER"
and "BRG" LEDs will alternately flash for a 6 seconds to show the default settings
have been loaded. The amplifier will then start as normal.
In addition to the parameters reset using the external user reset, the internal
user reset will also zero the system up timers, the power cycles counter, and the
max. temperature record.
A full factory reset is also available – please contact us for more details.
Remember to restore the link before refitting the cover, or it will set the
amplifier to default settings every time it is powered up!