Inner Dataset
60 x 5. Maintenance and Calibration
®
Arm (Calibration Tool, 221-672-1, Required)
Press
"Setup/Cal" button once. "CAL" is displayed.
Press
"Next" button. "CAL" is displayed at inner Dataset
is displayed if equipped with outer Dataset
Press
"Enter" to begin calibration. The step numbers are shown on the display,
starting with "Stp -1-." Each step is described below.
NOTE:
Turn the distance dimension knob to backup to a previous
cal step.
Verify that the inner arm is not extended, is in the "home" position, and is
not moving. Tap the foot pedal once or press "Enter."
Place the calibration tool on the shaft, using the spindle shaft slot located
closest to the middle of the calibration tool, as shown. Rotate the
calibration tool slowly by hand, clockwise until there is a beep, and the
step number changes to "-3-."
Position the calibration tool parallel to the floor. Tap the foot pedal once
or press "Enter."
Place the inner Dataset
foot pedal once or press "Enter."
Move the inner Dataset
once or press "Enter."
Move the inner Dataset
once or press "Enter."
®
arm.
®
arm at upward position "1" as shown. Tap the
®
arm to upward position "2." Tap the foot pedal
®
arm to upward position "3." Tap the foot pedal
DSP9200 Series Balancer Operation Instructions
®