3.8 Static / ALU Balancing Procedure (Adhesive Weight)

DSP9200 Series Balancer Operation Instructions
Use STATIC / ALU procedure for "static" (single-plane) balancing using an adhesive
weight. Because "static" balancing depends on the placement of only one weight, in
this procedure only one adhesive weight is shown, not an additional clip-on or
adhesive weight.
Mount wheel.
Press the
"Static/Dynamic" button to select STATIC
Press the
"Standard/ALU" button to select one adhesive weight.
Measure and enter the internal diameter and distance near the center of wheel as
shown below:
This measurement can be input automatically, if the DSP9200 is equipped with the
optional auto inner and/or outer Dataset
If necessary, use the "Split Spoke" feature. Refer to "Split Spoke Feature," page 53.
Close safety hood and spin wheel. After wheel stops, raise safety hood.
The 360 degree weight angle display can be used to place the adhesive weight at
Bottom Dead Center (BDC) for easier and more accurate placement than the
.
®
arms.
3. Balancing a Wheel x 41