3.6 Static / Standard Balancing Procedure (Clip-on Weight)

DSP9200 Series Balancer Operation Instructions
Verify balance condition by spinning again. Display should show "zero."
"Standard" balancing procedure is complete.
NOTE:
Weight digits blink if the force signals are larger than the
measurement range of the balancer. If this occurs, check for
wheel not being properly centered on spindle shaft. If wheel
is centered, apply the displayed weights. The blinking
weights indicate that a second spin and additional weight(s)
may be required to get zero imbalance. Refer to "Correcting
Large Imbalances," page 52.
Use STATIC / STANDARD balancing procedure for "static" (single-plane) balancing
using a clip-on weight.
Mount wheel.
Press the
"Static/Dynamic" button to select STATIC
Press the
"Standard/ALU" button until both clip-on weights are blinking.
Measure and enter the rim diameter of static plane weight location as shown below:
.
3. Balancing a Wheel x 35