Panasonic KW2G User Manual page 102

Eco-power meter
Hide thumbs Also See for KW2G:
Table of Contents

Advertisement

Data register
DT02000+N*100+30
DT02000+N*100+31
DT02000+N*100+32
DT02000+N*100+33
DT02000+N*100+34
DT02000+N*100+35
DT02000+N*100+36
DT02000+N*100+37
DT02000+N*100+38
DT02000+N*100+39
DT02000+N*100+40
DT02000+N*100+41
DT02000+N*100+42
DT02000+N*100+43
DT02000+N*100+44
DT02000+N*100+45
DT02000+N*100+46
DT02000+N*100+47
DT02000+N*100+48
DT02000+N*100+49
DT02000+N*100+50
DT02000+N*100+51
N: Unit number
Main unit: N=0 Expansion unit: N=1 to 7
nd
*1 Data of 2
circuit of single-phase two-wire system will be entered in name with *1.
*2 Data will be entered according to the setting system as below table in name with *2.
・Current
system
・Voltage
system
*3 Only for the main unit and one expansion unit. ('N' is 0 or 1.)
Note1) R: Read W: Write
2) Data register except specified is 0.
3) If each setting value is written by communication, it memories to internal EEPROM at the same
time. Therefore, change setting frequently makes EEPROM's life short. Avoid to usage like this.
However, general-purpose output judgement value is not written.
4) Write a data within the range when you write it.
5) Max reading point is 26 points (57-byte); max writing point is 23 points (55-byte).
6) When you use KW1M-R Eco-POWER METER (AKW1000) as a transmission device, DT00500
to 00502 can't be used. AKW1000 returns responses to the upper device.
Name
ON-time2 (1) *3
ON-time2 (2) *1 *3
ON-time2 (2) *1 *3
Ratio of ON-time1 (1)
*3
Ratio of ON-time2 (1)
*3
Ratio of ON-time1 (2)
*1 *3
Ratio of ON-time2 (2)
*1 *3
Maintenace flag (1) *3
Maintenace flag (2)
*1 *3
Maintenace time (1)*3
Maintenace time (1)*3
Maintenace time (2)
*1 *3
Maintenace time (2)
*1 *3
Hour meter status (1)
*3
Hour meter status (2)
*1 *3
Measuring point
1P2W
DT00134 - 00135
1P3W
3P3W
Measuring point
1.R-V / R-V / RS-V
1P2W
DT00124 - 00125
1P3W
DT00170 - 00171
3P3W
Unit
Kind of data
0.1h
Unsigned 32bit
1min
Unsigned 32bit
0.1h
Unsigned 32bit
0.1%
Unsigned 16bit
0.1%
Unsigned 16bit
0.1%
Unsigned 16bit
0.1%
Unsigned 16bit
Unsigned 16bit
Unsigned 16bit
1min
Unsigned 32bit
0.1h
Unsigned 32bit
1min
Unsigned 32bit
0.1h
Unsigned 32bit
Unsigned 16bit
Unsigned 16bit
1.R-A / R-A
DT00136 - 00137
DT00126 - 00127
DT00172 - 00173
93
KW2G / KW2G-H Eco-POWER METER
Range
0 to 999999
0 to 5999994
0 to 999999
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0: not available
1: available
0: not available
1: available
0 to 5999994
0 to 999999
0 to 5999994
0 to 999999
0: OFF-time
1: ON-time1
2: ON-time2
3: Maintenace time
0: OFF-time
1: ON-time1
2: ON-time2
3: Maintenace time
N-A / S-A
2.R-A / T-A
DT00138 - 00139
RT-V
2R-V / T-V / TS-V
DT00128 – 00129
DT00174 - 00175
R/W
R/W
R
R/W
R
R
R
R
R/W
R/W
R
R/W
R
R/W
R
R

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kw2g-h

Table of Contents