Mitsubishi Electric FR-A700 Series Instruction Manual page 98

Hide thumbs Also See for FR-A700 Series:
Table of Contents

Advertisement

Parameter
Name
29
Acceleration/
deceleration pattern
selection
Backlash
acceleration
140
stopping frequency
Backlash
acceleration
141
stopping time
Backlash
deceleration
142
stopping frequency
Backlash
deceleration
143
stopping time
Acceleration S-
380
pattern 1
Deceleration S-
381
pattern 1
Acceleration S-
382
pattern 2
Deceleration S-
383
pattern 2
S-pattern time at a
516
start of acceleration
S-pattern time at a
completion of
517
acceleration
S-pattern time at a
518
start of deceleraiton
S-pattern time at a
completion of
519
deceleraiton
Regenerative
30
function selection
Special regenerative
70
brake duty
Incre
Initial
Range
ments
Value
0
Linear acceleration/ deceleration
1
S-pattern acceleration/deceleration A
2
S-pattern acceleration/deceleration B
1
0
3
Backlash measures
4
S-pattern acceleration/deceleration C
5
S-pattern acceleration/deceleration D
0.01Hz
1Hz
0 to 400Hz
0.1s
0.5s
0 to 360s
Set the stopping frequency and time for
backlash measures.
Valid when Pr. 29 = "3"
0.01Hz
1Hz
0 to 400Hz
0.1s
0.5s
0 to 360s
Valid when S-pattern acceleration/
1%
0%
0 to 50%
deceleration C (Pr. 29 = 4) is set.
Set the time taken for S-pattern from
1%
0%
0 to 50%
starting of acceleration/deceleration to
linear acceleration as % to the
acceleration/deceleration time (Pr. 7, Pr. 8,
1%
0%
0 to 50%
etc.)
An acceleration/deceleration pattern can
1%
0%
0 to 50%
be changed with the X20 signal.
0.1s
0.1s
0.1 to 2.5s
Valid when S-pattern acceleration/
0.1s
0.1s
0.1 to 2.5s
deceleration D (Pr. 29 = 5) is set.
Set the time taken for S-pattern
acceleration/deceleration (S-pattern
0.1s
0.1s
0.1 to 2.5s
operation).
0.1s
0.1s
0.1 to 2.5s
0
Built-in brake, brake unit (FR-BU, BU)
High-duty brake resistor (FR-ABR),
1
Brake unit (MT-BU5),
Power regeneration converter (MT-RC)
High power factor converter (FR-HC, MT-
HC),
2
Power regeneration common converter
(FR-CV)
Built-in brake unit,
10
brake unit (FR-BU,
1
0
BU)
High-duty brake
11
resistor (FR-ABR),
brake unit (MT-BU5)
Built-in brake unit,
20
brake unit (FR-BU,
BU)
High-duty brake
21
resistor (FR-ABR),
brake unit (MT-BU5)
You can set the brake duty when a brake
unit or power regeneration converter is
0 to 30/
0.1%
0%
used.
0 to 10%*
* Range differ according to the inverter
Description
DC feeding mode 1
(operated by DC
feeding only)
DC feeding mode 2
(operated by
switching between
AC and DC)
capacity. (55K or less/75K or more)
Parameter List
All
Param
Param
param
eter
eter
eter
copy
clear
clear
: enabled
× : disabled
3
93

Advertisement

Table of Contents
loading