Parameter
Name
RUN terminal
190
function selection
SU terminal
191
function selection
IPF terminal
192
function selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal
195
function selection
ABC2 terminal
196
function selection
Incre
Initial
Range
ments
Value
0, 100: Inverter running
1, 101: Up to frequency
0 to 8,
1
0
2, 102: Instantaneous power failure/
10 to 20,
25 to 28,
3, 103: Overload alarm
30 to 36, 39,
4, 104: Output frequency detection
41 to 47,
5, 105: Second output frequency detection
1
1
64, 70, 84,
6, 106: Third output frequency detection
85, 90 to 99,
7, 107: Regenerative brake pre-alarm
100 to 108,
8, 108: Electronic thermal relay function
110 to 116,
10, 110:PU operation mode
120,
1
2
11, 111: Inverter operation ready
125 to 128,
12, 112:Output current detection
130 to 136,
13, 113:Zero current detection
139,
14, 114:PID lower limit
141 to 147,
1
3
15, 115:PID upper limit
164, 170,
16, 116:PID forward/reverse rotation
190 to 199,
9999
17, —: Commercial power-supply
1
4
18, —: Commercial power-supply
19, —: Commercial power-supply
20, 120:Brake opening request
25, 125:Fan fault output
1
99
26, 126:Heatsink overheat pre-alarm
27, 127:Orientation in-position *
28, 128:Orientation error *
30, 130:Forward rotation output *
31, 131:Reverse rotation output *
32, 132:Regenerative status output *
33, 133:Operation ready 2
34, 134:Low speed output
0 to 8,
35, 135:Torque detection
10 to 20,
36, 136:In-position *
25 to 28,
39, 139:Start time tuning completion
30 to 36, 39,
41, 141:Speed detection
41 to 47, 64,
42, 142:Second speed detection
70, 84, 85,
43, 143:Third speed detection
90, 91,
44, 144:Inverter running 2
94 to 99,
45, 145:Inverter running and start command
100 to 108,
46, 146:During deceleration at occurrence
110 to 116,
120,
125 to 128,
47, 147:During PID control activated
130 to 136,
64, 164:During retry
139,
70, 170:PID output interruption
141 to 147,
1
9999
84, 184:PreparatDC current feedingion
164, 170,
190, 191,
85, 185:DC current feeding
194 to 199,
90, 190:Life alarm
9999
91, 191:Alarm output 3 (power-off signal)
92, 192:Energy saving average value
93, 193:Current average monitor signal
94, 194:Alarm output 2
95, 195:Maintenance timer signal
96, 196:Remote output
97, 197:Minor fault output 2
98, 198:Minor fault output
99, 199:Alarm output
9999: No function
0 to 99: Positive logic
100 to 199: Negative logic
* Available only when used with the FR-A7AP.
Parameter List
Description
undervoltage
pre-alarm
output
switchover MC1
switchover MC2
switchover MC3
is on
of power failure (retained until
release)
ready signal *
updated timing
All
Param
Param
param
eter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
3
×
111