Mitsubishi Electric FR-A700 Series Instruction Manual page 107

Hide thumbs Also See for FR-A700 Series:
Table of Contents

Advertisement

Parameter List
Parameter
Motor excitation
82
current
83
Motor rated voltage
84
Rated motor frequency
Motor constant (R1)
90
Motor constant (R2)
91
Motor constant (L1)
92
Motor constant (L2)
93
Motor constant (X)
94
Auto tuning setting/
96
status
Second motor
455
excitation current
Rated second
456
motor voltage
Rated second
457
motor frequency
102
Incre
Initial
Name
ments
Value
0.01/
9999
0.1A
*
200/
0.1V
400V *
0.01Hz
60Hz
0.001Ω/
9999
0.01mΩ *
0.001Ω/
9999
0.01mΩ *
0.001Ω
(0.1mH)
9999
/0.01mΩ
(0.01mH) *
0.001Ω
(0.1mH)
9999
/0.01mΩ
(0.01mH) *
0.01Ω
(0.1%)/
9999
0.01Ω
(0.01%) *
1
0
0.01/
9999
0.1A *
200/
0.1V
400V *
0.01Hz
60Hz
Range
Description
Tuning data
(The value measured by offline auto tuning
0 to 500/
is automatically set.)
* The increments and setting range differ
0 to 3600A *
according to the inverter capacity. (55K or
less/75k or more)
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA) constants
Set the rated motor voltage(V).
0 to 1000V
* The initial values differ according to the
voltage level. (200V/400V)
10 to 120Hz Set the rated motor frequency (Hz).
Tuning data
(The value measured by offline auto tuning
0 to 50Ω/
is automatically set.)
0 to 400mΩ *
* The increments and setting range differ
according to the inverter capacity. (55K or
less/75k or more)
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA) constants
Tuning data
(The value measured by offline auto tuning
0 to 50Ω/
is automatically set.)
* The increments and setting range differ
0 to 400mΩ *
according to the inverter capacity. (55K or
less/75k or more)
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA) constants
Tuning data
0 to 50Ω (0 to
(The value measured by offline auto tuning
1000mH)/
is automatically set.)
* The increments and setting range differ
0 to 3600mΩ
according to the inverter capacity. (55K or
(0 to 400mH) *
less/75k or more)
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA) constants
Tuning data
0 to 50Ω (0 to
(The value measured by offline auto tuning
1000mH)/
is automatically set.)
* The increments and setting range differ
0 to 3600mΩ
according to the inverter capacity. (55K or
(0 to 400mH) *
less/75k or more)
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA) constants
Tuning data
0 to 500Ω
(The value measured by offline auto tuning
(0 to 100%)/
is automatically set.)
* The increments and setting range differ
0 to 100Ω
according to the inverter capacity. (55K or
(0 to 100%) *
less/75k or more)
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA) constants
0
Auto tuning is not performed
1
Tuning performed without motor running
101
Tuning performed with motor running
Tuning data of the second motor
(The value measured by offline auto tuning
0 to 500/
is automatically set.)
0 to 3600A *
* The increments and setting range differ
according to the inverter capacity. (55K or
less/75k or more)
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA) constants
Set the rated voltage (V) of the second
motor.
0 to 1000V
* The initial values differ according to the
voltage level. (200V/400V)
Set the rated frequency (Hz) of the second
10 to 120Hz
motor.
All
Param
Param
param
eter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×
×