Parameter
Name
Second motor
458
constant (R1)
Second motor
459
constant (R2)
Second motor
460
constant (L1)
Second motor
461
constant (L2)
Second motor
462
constant (X)
Second motor auto
463
tuning setting/status
Tuning data unit
684
switchover
Torque current
859
Second motor
860
torque current
89
Refer to Pr. 81.
90 to 94
Refer to Pr. 82 to Pr. 84.
Online auto tuning
95
selection
Second motor
574
online auto tuning
Incre
Initial
Range
ments
Value
Tuning data of the second motor
(The value measured by offline auto tuning
0 to 50Ω/
is automatically set.)
0.001Ω/
0 to 400mΩ *
9999
* The increments and setting range differ
0.01mΩ *
9999
Use the Mitsubishi motor (SF-JR, SF-HRCA) constants
Tuning data of the second motor
(The value measured by offline auto tuning
0 to 50Ω/
is automatically set.)
0.001Ω/
0 to 400mΩ *
9999
* The increments and setting range differ
0.01mΩ *
9999
Use the Mitsubishi motor (SF-JR, SF-HRCA) constants
Tuning data of the second motor
0 to 50Ω (0 to
(The value measured by offline auto tuning
0.001Ω
1000mH)/
is automatically set.)
(0.1mH)/
0 to 3600mΩ
9999
* The increments and setting range differ
0.01mΩ
(0 to 400mH) *
(0.01mH) *
9999
Use the Mitsubishi motor (SF-JR, SF-HRCA) constants
Tuning data of the second motor
0 to 50Ω (0 to
(The value measured by offline auto tuning
0.001Ω
1000mH)/
is automatically set.)
(0.1mH)
0 to 3600mΩ
9999
* The increments and setting range differ
/0.01mΩ
(0 to 400mH) *
(0.01mH) *
9999
Use the Mitsubishi motor (SF-JR, SF-HRCA) constants
Tuning data of the second motor
0 to 500Ω
(The value measured by offline auto tuning
0.01Ω
(0 to 100%)/
is automatically set.)
(0.1%)/
0 to 100Ω
* The increments and setting range differ
9999
0.01mΩ
(0 to 100%) *
(0.01%) *
9999
Use the Mitsubishi motor (SF-JR, SF-HRCA) constants
Set the tuning mode of the second motor.
1
0
0, 1, 101
(same as Pr. 96)
0
Internal data converter value
1
0
Displayed in "A, Ω, mH, %".
1
Tuning data
(The value measured by offline auto tuning
0 to 500/
is automatically set.)
0.01/
0 to 3600A *
9999
* The increments and setting range differ
0.1A *
9999
Use the Mitsubishi motor (SF-JR, SF-HRCA) constants
Tuning data of the second motor
(The value measured by offline auto tuning
0 to 500/
is automatically set.)
0.01/
0 to 3600A *
9999
* The increments and setting range differ
0.1A *
9999
Use the Mitsubishi motor (SF-JR, SF-HRCA) constants
0
Online auto tuning is not performed
1
0
1
Start-time tuning (at start-up)
2
Magnetic flux observer (normal)
Select the second motor online auto
1
0
0, 1
tuning. (same as Pr. 95)
Description
according to the inverter capacity. (55K or
less/75k or more)
according to the inverter capacity. (55K or
less/75k or more)
according to the inverter capacity. (55K or
less/75k or more)
according to the inverter capacity. (55K or
less/75k or more)
according to the inverter capacity. (55K or
less/75k or more)
according to the inverter capacity. (55K or
less/75k or more)
according to the inverter capacity. (55K or
less/75k or more)
Parameter List
All
Param
Param
param
eter
eter
eter
copy
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×
×
3