Chapter 7
Settings and configuration
Start Mode
Back
Figure 6: Start mode
Stop Mode
Torque
Back
Figure 7: Stop mode
In= 0000
Out= 0000
Back
Figure 8: Input/outputs
2003-02-05
10:33
Back
Figure 9: Real time clock
Keypad is
Active
Back
Figure 10: Keypad status
Change Password
Select
Back
Figure 11: Change Password
86
Volt
Start mode
The start mode of the motor is displayed. The possible
options are:
• Volt
• Torque
Stop mode
The stop mode of the motor is displayed. The possible
options are:
• Volt
• Torque
Status of inputs/outputs
The status of the Programmable inputs and outputs is
displayed with "0" for not activated or "1" for activated. The
figures have following function:
In=0100
Start signal high
In=1000
Stop signal high
In=0010
In0 high
In=0001
In1 high
Out=1000
Relay K4 activated
Out=0100
Relay K5 activated
Out=0010
Relay K6 activated
Out=0001
SW V7 activated
Real time clock
The real time clock shows present date and time.
How to set date, time and display type see "Presentation
Settings" .
Keypad status
Information on whether the keypad is locked or unlocked.
How to operate, see Chapter 6 "Human-Machine Interface
(HMI)" .
Change Password
Menu for changing the password. How to operate, see
Chapter 6 "Human-Machine Interface (HMI)" .