13.8 Pressure test
The Rapid injector is used as a pressure
test point.
1. Connect the pressure gauge to the
Rapid injector.
2. Examine the supply pressure by
turning the Rapid burner and one
other burner fully on, and lighting
them. The pressure must be:
a) 20 mbar for Natural Gas
b) 29 mbar for LPG, butane only
c) 37 mbar for LPG, propane only.
3. Turn the taps off and disconnect the
pressure gauge.
4. Make sure that all burners work
correctly.
13.9 Checking the hob burners
1. Lift the lid.
2. Put on the burner crowns and caps.
Make sure that they are correctly
seated.
3. Put on the pan supports.
4. Light one of the hob burners.
To light the hob burner refer to the
"Ignition of the hob burners".
Check if the flame is regular.
Check each of the burners.
5. Turn the knob for the hob to the off
position.
13.10 Checking the oven
burners and the grill
1. Put in the deep pan and the trivet.

14. ENERGY EFFICIENCY

14.1 Product information for hob according to EU 66/2014
Model identification
Type of hob
Number of gas burners
Energy efficiency per gas
burner (EE gas burner)
Energy efficiency for the gas hob (EE gas hob)
2. Light the oven burner.
To light the oven burner refer to the
"Ignition of the oven burners".
Check if the flame is regular.
Check each of the burners.
3. Turn the knob to the off position.
13.11 Checking the Lid Safety
Device
1. Lift the lid.
2. Light one of the hob burners.
To light the hob burner refer to the
"Ignition of the hob burners".
3. Close the lid. There should be no gas
supply to the hob burners. The
burner goes out.
4. Turn the knob to the off position and
lift the lid. The gas supply should be
restored to the hob burners, when
you turn the knob on.
13.12 Electrical installation
This appliance is supplied with a main
plug and a main cable.
17166GT-MN
Hob inside Freestanding Cooker
4
Left Front - Triple Crown
Left rear - Semi Rapid
Right front - Auxiliary
Right rear- Semi Rapid
WARNING!
The manufacturer is not
responsible if you do not
follow the safety precautions
from Safety chapters.
The spark generator is active
all the time if the phases are
not connected correctly.
52.8 %
54.6 %
not applicable
54.6 %
54.0 %

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents