Chapter 2 Useful Features
(2)
Power Control Configuration submenu
From the Server menu, move the cursor to Power Control Configuration and then press the <Enter> key to
show its submenus.
For details about the options, see the table below.
Option
AC-LINK
Power ON Delay Time Mode
Delay Time
Standby Power Save
Parameter
Stay Off
[Last State]
Power On
[Manually Setting]
Random
[45]-600
[Disabled]
Enabled
Express5800/R120f-2E, T120f
Description
Specify the AC linking feature. Specify how the DC power
state should be when the AC power is supplied again after
loss of power. (See the table below)
Select a method to specify the delay time before powering
on DC power. Available options are: "User-specified value"
or "random value".
This option is selectable when AC-LINK is set to "Power
On" or "Last State".
Specify the delay time in unit of seconds.
The minimum configurable time may be changed from the
factory-set value.
The minimum configurable time is displayed when
executing Load Setup Defaults.
This menu appears when Power ON Delay Time Mode is
set to "Manually Setting".
Enable or disable the feature that saves the standby power
on standby. If this option is set to "Enabled", the AC-LINK
setting is fixed to "Power On" automatically and cannot be
changed. When the AC power is off, management,
monitoring, and power-on of the server are disabled on a
remote site. Powering on the server is available only by
pressing the POWER switch on the server.
If the AC-LINK setting is changed on a remote site with this
option being set, you need to press the POWER switch
twice to power on the server.