NEC Express5800/T120f Maintenance Manual page 192

Express5800 series
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
DXE_PCI_BUS_OUT_OF_RESOURCES
B800
C000
The error occurred during
fan sensor reading.
C010
The error occurred during
temperature sensor reading
C011
System Temperature out of
the range.
C020
The error occurred during
voltage sensor reading.
C021
System Voltage out of the
range.
C040
SROM data read error
C061
1st SMBus device Error
detected.
C062
2nd SMBus device Error
detected.
C063
3rd SMBus device Error
detected.
C064
4th SMBus device Error
detected.
C065
5th SMBus device Error
detected.
C066
6th SMBus device Error
detected.
C067
7th SMBus device Error
detected.
C068
8th SMBus device Error
detected.
C101
BMC Memory Test
Failed.
C102
BMC Firmware Code
Area CRC check Failed.
C103
BMC core hardware failure.
C104
BMC IBF or OBF check failed.
C105
BMC SEL area full.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC FRU
corrupted.
C10E
BMC SDR Repository empty.
C10F
IPMB signal lines do not
respond.
C110
BMC FRU device failure.
C111
BMC SDR Repository failure.
C112
BMC SEL device failure.
C113
BMC RAM test error.
C114
BMC Fatal hardware error.
192
Cause
Resources to be allocated to
PCI expansion card was
insufficient.
An error was detected while
reading fan sensor.
An error was detected while
reading temperature sensor.
A temperature abnormality was
detected.
An error was detected while
reading voltage sensor.
A system voltage abnormality
was detected.
An error was detected while
reading data on SROM.
An error was detected on 1st
SM Bus.
An error was detected on 2nd
SM Bus.
An error was detected on 3rd
SM Bus.
An error was detected on 4th
SM Bus.
An error was detected on 5th
SM Bus.
An error was detected on 6th
SM Bus.
An error was detected on 7th
SM Bus.
An error was detected on 8th
SM Bus.
An error was detected on BMC.
An error was detected while
accessing BMC.
There is not enough space to
store the system event log.
An illegality was detected while
updating BMC firmware.
An illegality was detected in
FRU containing the device
information.
An error was detected on BMC
SDR.
Failure of Satellite Management
Controller was detected.
An error was detected in FRU
that contains device
information.
Failure was detected in SROM
that stores the SDR.
Device failure was detected in
BMC SEL.
An error was detected in BMC
RAM.
A hardware error was detected
in BMC.
Express5800/R120f-2E, T120f
Solution
Contact your sales representative.
The cooling fan has failed or is clogged.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
Run Offline Tools (Chapter 1, 9. Offline Tools)
and delete the event logs.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
Maintenance Guide
1. POST Error Message

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/r120f-2e

Table of Contents