Avaya callpilot 1002rp Hardware Installation page 57

Hide thumbs Also See for callpilot 1002rp:
Table of Contents

Advertisement

To connect the 1002rp DC server to power
1.
2. Connect the other end of the DC power cable to the PDU. Use the supplied clips
3. Turn on the PDU.
To start the server
1. Press the server power switch to start the server.
2. Observe the Power-On Self Test (POST) and initialization messages on the monitor.
3. Let the mini-setup sequence run until you are prompted to login to the operating
®
Avaya CallPilot
1002rp Server Hardware Installation
Danger:
Risk ofelectrical shock
• Only qualified personnel can alter electrical connections.
• Ensure the power distribution unit (PDU) is turned off until you are instructed
to turn it on.
Connect the DC power cable to the server.
and screws to secure the plugs.
The following photograph shows the keyed plug of the DC power cable. This plug
connects to the PDU:
Note:
If you are not using a Avaya-supplied PDU, have a qualified electrician connect
the cable appropriately to your DC power plant. The 1002rp uses a negative 48
V power supply, therefore the red cable is negative (-48 V) and the black cable
is the ground (GND).
system.
Before you begin
December 2010
57

Advertisement

Table of Contents
loading

Table of Contents