UM2027
12
Test points
The different test points available on the STEVAL-IHT008V1 are given in the table below.
Reference
TP1
TP2, TP21,
TP33
TP3
TP4
TP5
TP6
TP7
TP8
TP9
TP10
TP11
TP12
TP13
TP14,
TP24,TP29
TP15
TP16
TP17
TP18
TP19
TP20
TP22
TP23
TP25
TP26
TP27
TP28
TP30
TP31
TP32
TP34
Table 6: Test points
Designation
L1
VCC_AC
HVDC
L
OUT_ICL
OUT1
OUT2
OUT3
OUT4
OUT5
HVDC/2
N
N1
GND_DC
G1
G2
G3
G4
G5
G_ICL
GND_AC
15V_DC
VCC_INS
Drain_viper
GND_INS
5V_DC
ZVS
VL1_MEAS
VN1_MEAS
MAX INRUSH CURRENT ORDER
DocID029048 Rev 1
Test points
Definition
Line after EMI filter
Line before EMI filter
A2 output of T_ICL
A2 output of T1
A2 output of T2
A2 output of T3
A2 output of T4
A2 output of T5
Neutral before EMI filter
Neutral after EMI filter
Gate signal of T1
Gate signal of T2
Gate signal of T3
Gate signal of T4
Gate signal of T5
Gate signal of T_ICL
MCU input for line
measurement
MCU input for neutral
measurement
35/37
Need help?