5. Assembly

This section describes the external supply/connection ports of the Synchroprint and the points to be
observed during assembly.
5.1.

General Assembly Instructions

The Synchroprint must only be installed / assembled by an authorized MHM
service technician or by an authorized service technician from an official
MHM dealer/agent. Any assembly/installation by any third party not listed
above will result in immediate cancellation of the warranty.
The customer should have a minimum of two persons available to assist the technician with the
installation and assembly of the machine.
5.2.

Positioning of the Synchroprint

The machine must be mounted on a bed with sufficient load-bearing capacity. In case of doubt this
capacity has to be examined by a structural engineer.
In order to guarantee perfect installation and smooth operation of the Synchroprint, the machine
must be installed at a sufficient distance from adjacent elements of the building (walls, columns,
etc.) and/or other machines. The distance required in each case depends on the screen size, and must
be chosen so as to allow the operator to replace the screens without any problems. The dimensions
of the respective machine are indicated in Chapter "3 Data".
5.3.

Ambient Conditions

For the electrical equipment on the Synchroprint, ambient conditions according to standard IEC
60204 "Electrical Equipment of Industrial Machines" should be observed.
The following points should be observed in order to achieve efficient running and an optimum level
of production with the Synchroprint:
1. The premises, where the Synchroprint is to be operated, must be kept clean, dry and well-
aired.
2. The ambient temperature must not fall below +5° C or exceed +45° C.
3. Relative air humidity must not exceed 80 %.
4. The mains supply must not exceed or fall below a tolerance of +/- 5 % of the required
voltage for the Synchroprint. If this voltage stability cannot be guaranteed, the customer
must install a constant-voltage regulator to protect the Synchroprint against such
fluctuations.
5. The compressed air must be clean, filtered and dry (class 1:4:1 according ISO8573-1:2010).
6. Compressed air supply must be sufficient in terms of pressure, volume and consistency.
7. Electricity supply should be sufficient with adequate fuse protection.
8. Maximum installation altitude is 2000m above sea level.
Operating instructions X-Type plus V1-3.docx
Operating Instruction X-Type plus
Page 13 of 45