INSTALLATION
3
V mode;1 rail (DN15...250)
Press "
Read from the display of the signal converter what rail configuration is required and what the
correct sensor distance is.
1.8
Advised sensor position
34.30 mm
Signal quality
< Previous | Next >
< Previous | Next >
< Previous | Next >
< Previous | Next >
13-04-2010 14:11:09
Please follow up the instructions for the application.
One rail with 2 transducers in V mode: Put the first transducer at position "0", the other one at
the recommended distance, shown on the screen (in this example 34.30 mm).
• Unlock the transducer by turning the locking knob 2 counter clockwise.
• Slide the transducer 1 to the new position 3.
• Lock the transducer by turning the locking knob 2 clockwise.
V mode; 2 rails (DN200...750)
INFORMATION!
For V mode with 2 rails you must install the DOWN rail in line with UP rail. It is easier to install
than the Z mode, but you need more free pipe length.